Analysis of Faults and Handling of Electromechanical Drainage and Irrigation Engineering Equipment
Electrification is a symbol of the modernization of agricultural production in China,and the construction and application of electromechanical irrigation and drainage projects is a specific manifestation of agricultural electrification.The effectiveness of electromechanical irrigation and drainage projects relies on various electrical equipment,among which the most important is the variable frequency drive(VFD)in the pumping station.During the operation of electromechanical irrigation and drainage projects,any equipment failure can affect the normal operation of the entire engineering system.In order to make electromechanical irrigation and drainage projects function better,it is necessary to strengthen the emphasis on equipment fault handling.Therefore,this article takes the VFD of the pumping station as the starting point,analyzes the common faults of the VFD and their causes,and proposes corresponding solutions to better handle equipment faults and ensure the efficiency of the operation of electromechanical irrigation and drainage projects.
electromechanical irrigation and drainage projectpumping stationvariable frequency drive(VFD)faultfault handling