首页|10kV配电线路的运维与检修探讨

10kV配电线路的运维与检修探讨

扫码查看
为确保电力系统的稳定运行,制定了巡检与检修计划,包括设备定期检查与维护保养;建立应急处置与故障排除流程,采用先进的故障诊断系统提高效率,基于数据分析更换老旧设备,增加避雷器数量并优化布局.运维与检修策略提升了 10 kV配电线路运行效率,绝缘电阻高于规定值并耐压试验通过.同时避雷器测试合格,泄漏电流远低于限值,预计升级改造将提高可靠性、安全性与运行效率,满足电力需求,提升供电质量和服务水平.
Discussion on Operation,Maintenance,and Overhaul of 10?kV Power Distribution Lines
To ensure the stable operation of the power system,an inspection and maintenance plan has been developed,including regular inspection and maintenance of equipment;establishing emergency response and troubleshooting procedures;adopting advanced fault diagnosis systems to improve efficiency;replacing outdated equipment based on data analysis;and increasing the number and optimizing the layout of lightning arresters.These operation,maintenance,and inspection strategies have improved the operational efficiency of 10 kV distribution lines,with insulation resistance exceeding the specified values and passing the withstand voltage test.Meanwhile,the lightning arresters have passed testing with leakage currents far below the limit.It is expected that the upgrading and renovation will improve reliability,safety,and operational efficiency,meeting power demand and enhancing power supply quality and service levels.

10 kV distribution lineengineering operation and maintenancetechnical inspection

温志刚

展开 >

国网冀北电力有限公司乐亭县供电分公司,河北 唐山 063600

10kV配电线路 工程运维 技术检修

2024

仪器仪表用户
天津仪表集团有限公司,中国仪器仪表学会节能技术应用分会

仪器仪表用户

影响因子:0.255
ISSN:1671-1041
年,卷(期):2024.31(11)