首页|复式钢管混凝土T形件单边螺栓节点承载力研究

复式钢管混凝土T形件单边螺栓节点承载力研究

扫码查看
T形件单边螺栓连接节点应用到复式钢管混凝土结构中可充分利用双层钢管的截面特点,传力性能好且抗震性能高。对5个节点试件进行柱端水平往复加载试验并进行了数值模拟分析,试验中T形件因加肋方式不同出现了 3种变形特征,而节点整体的破坏形态均为T形件屈服后钢梁塑性变形,数值模拟结果与试验结果吻合较好。根据试验和有限元结果分析了节点传力构件的受力机理,提出T形件受拉模型,分别计算T形件翼缘和加劲肋提供的抗弯承载力,从而得到节点的抗弯极限承载力计算公式,计算结果与试验结果误差较小,与数值模拟结果也十分相近。研究结果表明采用T形件受拉模型计算的节点承载力公式适用于T形件与单边螺栓强度相匹配的情况,T形件加肋形式对节点极限承载力影响最大,其次为T形件翼缘厚度,T形件腹板厚度影响很小;此外随着T形件翼缘厚度的增加节点承载力提高越来越小,故得出了单边螺栓直径与T形件翼缘厚度的最大临界值和最佳匹配值,为该节点工程应用提供理论参考和设计依据。
Study on bearing capacity of blind bolted T-shaped plate joints in composite CFST structures
Blind bolted T-shaped plate joints with good force transfer performance and high seismic performance,can make full use of the section characteristics of double steel tubes in composite concrete-filled steel tubular columns.Cyclic loading tests and numerical simulations on five blind bolted joints were conducted.There were three types of deformation characteristics of the T-shaped plate due to its different ribbed forms,but all the failure modes of the joints were plastic deformation of steel beams after T-shaped plates yielded.Numerical simulation results agreed well with the experimental results.A tensile model of the T-shaped plate was established according to the force-transferring mechanism based on the results of experiments and simulations.The bending bearing capacity of T-shaped plate flanges and stiffeners was calculated respectively,and the ultimate bearing capacity of the joint was calculated.The error between the calculated results and the experimental results is very small,and they are very close to the numerical simulation results.The results show that the calculation formula based on the tensile model of a T-shaped plate is suitable for the case of strength matching between T-shaped plates and blind bolts.The rib form of T-shaped plates has the greatest influence on the ultimate bearing capacity of the joint,followed by the flange thickness of T-shaped plates,and the web thickness of T-shaped plates has little influence.The maximum critical value and the best matching value between the diameter of the blind bolt and the flange thickness of T-shaped plates are obtained,which provides a theoretical reference and design basis for the application of this type of joint in composite structures.

composite concrete-filled steel tubeT-shaped plateblind boltlow cycle reciprocating loading testbending bearing capacity

张玉芬、卜鸿凡、高嘉岐

展开 >

河北工业大学土木与交通学院,300401天津

天津市装配式建筑与智能建造重点实验室,300401天津

复式钢管混凝土 T形件 单边螺栓 低周往复荷载试验 抗弯承载力

国家自然科学基金资助项目

52078179

2024

应用力学学报
西安交通大学

应用力学学报

CSTPCD北大核心
影响因子:0.398
ISSN:1000-4939
年,卷(期):2024.41(2)