首页|电磁超声SH波输电杆塔接地扁钢腐蚀缺陷检测

电磁超声SH波输电杆塔接地扁钢腐蚀缺陷检测

扫码查看
为实现接地扁钢腐蚀缺陷方便且快速的检测,提出了基于电磁超声SH波检测接地扁钢腐蚀缺陷的方法.建立接地扁钢及其腐蚀缺陷的三维有限元仿真模型,分析接地扁钢中SH0波的传播情况以及其缺陷检测时的衰减特性.结果表明,随着SH0波传播距离的增大,其回波信号位移幅值减小,且下降幅度逐渐减缓,并有转向稳定的趋势;腐蚀缺陷深度和长度增加会导致回波信号幅值增大,而腐蚀缺陷宽度对回波幅值影响很小.通过实验探究不同腐蚀缺陷对检测结果的影响,验证了电磁超声SH0波检测接地扁钢腐蚀缺陷的可行性.仿真和实验结果表明,电磁超声检测方法可以准确判断接地扁钢缺陷的位置.该方法为现场接地扁钢腐蚀缺陷的检测以及量化识别提供新思路,具有重要参考价值.
Detection of corrosion defect of ground flat steel of transmission pole tower by electromagnetic ultrasonic SH wave
In order to achieve convenient and rapid detection of corrosion defects in grounded flat steel,a method based on electromagnetic ultrasonic SH wave detection of corrosion defects in grounded flat steel is proposed.A three-dimensional finite element simulation model of the grounded flat steel and its corrosion defects was established,and the propagation of SH0 waves in the grounded flat steel and the attenuation characteristics of its defect detection were analyzed.The results show that,with the increase of SH0 wave propagation distance,its echo signal displacement amplitude decreases,and the decline gradually slows down,and has a tendency to turn stable;corrosion defect depth and length will lead to an increase in the echo signal amplitude,while the corrosion defect width on the echo amplitude effect is very small.Through the test to explore the impact of different corrosion defects on the detection results,to verify the feasibility of electromagnetic ultrasound SH0 wave detection of corrosion defects of grounded flat steel.Simulation and test results show that the electromagnetic ultrasonic detection method can accurately determine the location of grounding flat steel defects.This method provides new ideas for the detection of corrosion defects of grounded flat steel in the field as well as quantitative identification,which has important reference value.

Transmission pole towersGround flat steelElectromagnetic ultrasonicSH waveFrequency dispersionDefect of corrosion

吕俊杰、方春华、张云杰、游海鑫、高广德、宋博、董晓虎、李长辉、侯新文

展开 >

三峡大学电气与新能源学院 宜昌 443002

国网湖北省电力有限公司超高压公司 武汉 430050

输电杆塔 接地扁钢 电磁超声 SH波 频散 腐蚀缺陷

电网环境保护国家重点实验室2022年度实验室开放基金项目

GYW5120221415

2024

应用声学
中国科学院声学研究所

应用声学

CSTPCD北大核心
影响因子:1.128
ISSN:1000-310X
年,卷(期):2024.43(4)