扬州大学学报(自然科学版)2024,Vol.27Issue(4) :8-21.DOI:10.19411/j.1007-824x.2024.04.002

真实非均匀受火边界下STRC柱的温度分布及材料性能退化分析

Analysis of the temperature distribution and material property degradation of STRC columns under real nonuniform fire boundary conditions

万鹏程 顾澔安 杨冬冬 王琨
扬州大学学报(自然科学版)2024,Vol.27Issue(4) :8-21.DOI:10.19411/j.1007-824x.2024.04.002

真实非均匀受火边界下STRC柱的温度分布及材料性能退化分析

Analysis of the temperature distribution and material property degradation of STRC columns under real nonuniform fire boundary conditions

万鹏程 1顾澔安 2杨冬冬 1王琨1
扫码查看

作者信息

  • 1. 扬州大学建筑科学与工程学院,江苏 扬州 225127
  • 2. 河海大学力学与工程科学学院,南京 211100
  • 折叠

摘要

为揭示真实火灾边界下钢管约束钢筋混凝土(steel tubed reinforced concrete,STRC)柱的耐火性能,采用 ABAQUS软件对考虑墙体影响的非均匀受火边界下方形 STRC 柱的温度场进行分析,获取了受火边界、墙体、柱截面尺寸、墙体导热系数和厚度等参数下受火柱的温度分布、钢材和混凝土的等效强度折减和弹性模量折减情况.结果表明:相较于无墙体受火边界,真实火灾边界下方形 STRC 柱的温度分布更不均匀,但等效强度折减系数总体上更高;非均匀受火柱的混凝土平均温度和钢管平均温度均低于四面受火柱,且受火面越少,构件整体温度越低,等效强度越高;构件整体温度和等效强度折减程度随柱截面尺寸、墙体厚度的增大和材料导热系数的减小而降低.

Abstract

In order to reveal the fire resistance of steel tubed reinforced concrete(STRC)column under real fire boundary,ABAQUS software is used to analyze the temperature field of square STRC column under nonuniform fire boundary considering the influence of wall.The temperature distribution of the STRC columns under various parameters such as fire boundaries,with or without walls,cross-sectional dimensions of the columns,thermal conductivity and thickness of the walls is discussed.The influences of parameters on the equivalent strength reduction and equivalent elastic modulus reduction of steel and concrete are evaluated.The results indicate that the temperature dis-tribution of square STRC columns under real fire boundaries is more uneven than that under fire boundaries without wall,but the equivalent strength reduction coefficient is generally higher.The average temperature of the concrete and steel tube of nonuniformly fire-exposed columns is lower than that of four sides of fire column,and the less the fire surface,the lower the overall tempera-ture of the component,the higher the equivalent strength.The overall temperature and the equiva-lent strength reduction level decrease with the increase of the column section size,thickness of the wall and the decrease of the thermal conductivity of the material.

关键词

钢管约束钢筋混凝土柱/真实非均匀受火边界/温度场/有限元分析

Key words

steel tubed reinforced concrete(STRC)column/real nonuniform fire boundary condi-tions/temperature field/finite element analysis(FEA)

引用本文复制引用

基金项目

国家自然科学基金青年科学基金(52308534)

江苏省自然科学基金青年科学基金(BK20220592)

教育部"春晖计划"合作科研基金(HZKY20220167)

江苏省研究生实践创新计划(SJCX23_1943)

出版年

2024
扬州大学学报(自然科学版)
扬州大学

扬州大学学报(自然科学版)

影响因子:0.473
ISSN:1007-824X
段落导航相关论文