原子能科学技术2024,Vol.58Issue(4) :705-713.DOI:10.7538/yzk.2024.youxian.0245

Uniformity Control of Scanned Beam in 300 MeV Proton and Heavy Ion Accelerator Complex at SESRI

HOU Lingxiao YUAN Youjin SHEN Guodong RUAN Shuang LIU Jie ZHU Yunpeng WANG Geng GUO Hongliang LYU Mingbang GAO Daqing XU Zhiguo SHENG Lina YANG Jiancheng
原子能科学技术2024,Vol.58Issue(4) :705-713.DOI:10.7538/yzk.2024.youxian.0245

Uniformity Control of Scanned Beam in 300 MeV Proton and Heavy Ion Accelerator Complex at SESRI

HOU Lingxiao 1YUAN Youjin 2SHEN Guodong 2RUAN Shuang 2LIU Jie 2ZHU Yunpeng 1WANG Geng 2GUO Hongliang 2LYU Mingbang 1GAO Daqing 2XU Zhiguo 2SHENG Lina 2YANG Jiancheng2
扫码查看

作者信息

  • 1. Institute of Modern Physics,Chinese Academy of Sciences,Lanzhou 730000,China;University of Chinese Academy of Sciences,Beijing 100049,China
  • 2. Institute of Modern Physics,Chinese Academy of Sciences,Lanzhou 730000,China
  • 折叠

Abstract

In recent years,heavy ion accelerator technology has been rapidly developing worldwide and widely applied in the fields of space radiation simulation and particle ther-apy.Usually,a very high uniformity in the irradiation area is required for the extracted ion beams,which is crucial because it directly affects the experimental precision and therapeutic effect.Specifically,ultra-large-area and high-uniformity scanning are crucial requirements for spacecraft radiation effects assessment and serve as core specification for beamline terminal design.In the 300 MeV proton and heavy ion accelerator complex at the Space Environment Simulation and Research Infrastructure(SESRI),proton and heavy ion beams will be accelerated and ultimately delivered to three irradiation termi-nals.In order to achieve the required large irradiation area of 320 mm× 320 mm,hori-zontal and vertical scanning magnets are used in the extraction beam line.However,considering the various requirements for beam species and energies,the tracking accura-cy of power supplies(PSs),the eddy current effect of scanning magnets,and the fluctu-ation of ion bunch structure will reduce the irradiation uniformity.To mitigate these effects,a beam uniformity optimization method based on the measured beam distribution was proposed and applied in the accelerator complex at SESRI.In the experiment,the uniformity is successfully optimized from 75%to over 90%after five iterations of adjustment to the PS waveforms.In this paper,the method and experimental results were introduced.

Key words

heavy ion accelerator/beam uniformity/scanning magnet/MIC

引用本文复制引用

基金项目

国家重点研发计划(2019YFA0405400)

出版年

2024
原子能科学技术
中国原子能科学研究院

原子能科学技术

CSTPCD北大核心
影响因子:0.372
ISSN:1000-6931
参考文献量15
段落导航相关论文