首页|不同标准对智能电表性能测试方法的差异化研究

不同标准对智能电表性能测试方法的差异化研究

扫码查看
主要研究了IEC标准和ANSI标准在精度等级、启动电流等测试方法的差异性.通过比较分析 2 种标准的相关内容,发现在精度等级、测试方法、测试环境等方面存在较大差异;同时,还针对差异性进行了深入讨论,并提出了解决方案,以便在实际工程应用中更好地处理标准差异带来的实际应用问题.
Research on the Differentiation of Performance Testing Methods for Smart Meters by Different Standards
Mainly studied the differences in testing methods suc h as accuracy level and starting current between IEC standards and ANSI standards.By comparing and analyzing the relevant content of the two standards,it was found that there are significant differences in accuracy levels,testing methods,testing environments,and other aspects.At the same time,in-depth discussions were conducted on differences and solutions were proposed to better address the practical application problems caused by standard differences in practical engineering applications.

IEC standardANSI standardaccuracy levelstarting current

俞斌奇、许棋樟、汪忠一、徐京生、陈太平、张宇明

展开 >

华立科技股份有限公司,浙江杭州 310023

广州宇阳电力科技有限公司,广东广州 510000

IEC标准 ANSI标准 精度等级 启动电流

2024

自动化应用
重庆西南信息有限公司

自动化应用

影响因子:0.156
ISSN:1674-778X
年,卷(期):2024.65(4)