首页|基于光纤通信的输电线路变压器运行状态自动监测方法

基于光纤通信的输电线路变压器运行状态自动监测方法

扫码查看
针对当前输电线路变压器监测效果不理想的问题,提出了基于光纤通信的输电线路变压器运行状态自动监测方法.该方法首先利用光纤通信技术对变压器绕组进行测温,获取变压器绕组温度信号,然后采用小波去噪法对获取的绕组温度信号进行滤波处理,最后通过对比绕组温度上限来识别变压器运行异常的状态,并对异常状态进行预警监测.经实验证明,设计方法异常状态识别率不低于98%,能够实现对输电线路变压器运行状态的精准监测,应用效果较好.
Automatic Monitoring Method of Transmission Line Transformer Operation Status Based on Optical Fiber Communication
Aiming at the problem of unsatisfactory monitoring results of current transmission line transformers,a method for automatic monitoring of the operation status of transmission line transformers based on fiber optic communication is proposed.This method first uses fiber optic communication technology to measure the temperature of the transformer winding and obtain the temperature signal of the transformer winding.Then,the wavelet denoising method is used to filter and process the obtained winding temperature signal.Finally,the abnormal operating status of the transformer is identified by comparing the upper limit of the winding temperature,and early warning and monitoring of the abnormal status are carried out.Experimental results have shown that the abnormal state recognition rate of the design method is not less than 98%,and it can achieve accurate monitoring of the operating status of transmission line transformers,with good application effects.

optical fiber communicationtransmission linetransformeroperation statusautomatic monitoringwavelet denoising method

程忠忠、高磊、张金朝

展开 >

安徽省响洪甸蓄能发电有限责任公司,安徽 六安 237000

光纤通信 输电线路 变压器 运行状态 自动监测 小波去噪法

2024

自动化应用
重庆西南信息有限公司

自动化应用

影响因子:0.156
ISSN:1674-778X
年,卷(期):2024.65(16)