针对传统输电线路危险源预警管控效果差的问题,介绍一种输电线路危险源预警管控系统设计方案.首先,针对输电线路危险源预警管控工作具体情况,分析系统需求;然后,以此为基础,分别设计系统总体框架、硬件模块及应用平台;最后,通过实验分析的方式,分析该系统的应用效果.结果表明,该系统功能良好,可实时监测输电线路危险源,且线路出现危险源后系统可自动发出警报,有利于及时处理输电线路危险源,从而提升整个输电线路运行的安全性与稳定性.
Research on Design of Danger Source Early Warning and Control System for Transmission Lines
In view of the poor effect of danger source early warning and control of traditional transmission lines,a design scheme of danger source early warning and control system for transmission lines is introduced.Firstly,based on the specific situation of danger source early warning and control of transmission lines,the system requirements are analyzed.Then,based on this,the overall system framework,hardware module and application platform are designed respectively.Finally,the application effect of the system is analyzed through experimental analysis.The results show that the system has good function and can monitor the transmission line danger source in real time,and the system can automatically issue an alarm after the danger source appears on the line,which is conducive to the timely processing of the transmission line danger source,thus improving the safety and stability of the entire transmission line operation.