自动化与仪器仪表2024,Issue(2) :250-254.DOI:10.14016/j.cnki.1001-9227.2024.02.250

新型配电系统多层级交直流数字高压表自动化计量校准方法

Automatic Measurement and Calibration Method for Multilayer AC/DC Digital High Voltage Meters in a New Distribution System

侯永辉 王赛爽 李帅 贾红斌
自动化与仪器仪表2024,Issue(2) :250-254.DOI:10.14016/j.cnki.1001-9227.2024.02.250

新型配电系统多层级交直流数字高压表自动化计量校准方法

Automatic Measurement and Calibration Method for Multilayer AC/DC Digital High Voltage Meters in a New Distribution System

侯永辉 1王赛爽 2李帅 2贾红斌1
扫码查看

作者信息

  • 1. 河南省计量测试科学研究院,郑州 450000
  • 2. 华北水利水电大学,郑州 450000
  • 折叠

摘要

针对数字高压表自动化计量精度不足问题,本文介绍了一种新型配电系统多层级交直流数字高压表自动化计量校准方法.该方法架设新型配电系统多层级交直流电网架构,并分析数字高压表在新型配电系统多层级交直流电网内的运行原理后,通过基于平均值原理的数字高压表自动化计量误差计算方法,获取高压表自动化计量新型配电系统多层级交直流电网电压误差数值,再设计高压表自动化计量校准装置后,并以该新型配电系统多层级交直流电网电压误差数值为基础,计算数字高压表自动化计量校准系数,利用该校准系数实现数字高压表自动化计量校准,同时分析数字高压表不确定度后,依据该不确定度对数字高压表自动化计量校准进行进一步优化,使数字高压表自动化计量结果更加精准.实验表明:该方法计算新型配电系统多层级交直流电网电压误差数值较为准确,可有效对数字高压表自动化计量进行校准,应用效果较为显著.

Abstract

In response to the problem of insufficient automatic measurement accuracy of digital high-voltage meters,this article introduces a new multi-level AC/DC digital high-voltage meter automatic measurement calibration method for distribution systems.This method establishes a multi-layer AC/DC power grid architecture for a new distribution system,analyzes the operating principle of digital high-voltage meters in the multi-layer AC/DC power grid of the new distribution system,and obtains the voltage error value of the new distribution system's multi-layer AC/DC power grid through the calculation method of automatic measurement error of digit-al high-voltage meters based on the average value principle.After designing an automatic measurement calibration device for high-voltage meters,Based on the voltage error values of the multi-layer AC/DC power grid in the new distribution system,the calibration coefficient for automatic measurement of digital high-voltage meters is calculated.This calibration coefficient is used to achieve auto-matic measurement and calibration of digital high-voltage meters.At the same time,after analyzing the uncertainty of digital high-voltage meters,further optimization and optimization of automatic measurement and calibration of digital high-voltage meters are car-ried out based on this uncertainty,making the automatic measurement results of digital high-voltage meters more accurate.The exper-iment shows that this method is more accurate in calculating the voltage error value of the multi-layer AC/DC power grid in the new distribution system,and can effectively calibrate the automatic measurement of digital high-voltage meters.The application effect is significant.

关键词

新型配电系统/多层级/交直流/数字高压表/自动化计量/校准方法

Key words

new distribution system/multi level/AC and DC/digital high-voltage meter/automated measurement/calibration method

引用本文复制引用

基金项目

河南省市场监督管理局科技攻关计划(2023)(2023sj09)

出版年

2024
自动化与仪器仪表
重庆工业自动化仪表研究所,重庆市自动化与仪器仪表学会

自动化与仪器仪表

CSTPCD
影响因子:0.327
ISSN:1001-9227
段落导航相关论文