中国包装科技博览2012,Issue(27) :332-333.

贯入法检测砌筑砂浆抗压强度曲线误差验证

ERROR VALIDATION FOR THE CURVE OF TESTING COMPRESSIVE STRENGTH OFMASONRY MORTAR BY PENETRATION RESISTANCE METHOD

余锦棠
中国包装科技博览2012,Issue(27) :332-333.

贯入法检测砌筑砂浆抗压强度曲线误差验证

ERROR VALIDATION FOR THE CURVE OF TESTING COMPRESSIVE STRENGTH OFMASONRY MORTAR BY PENETRATION RESISTANCE METHOD

余锦棠1
扫码查看

作者信息

  • 1. 温州市科正建设工程检测有限公司,浙江温州325006
  • 折叠

摘要

本文根据《贯入法检测砌筑砂浆抗压强度技术规程》JGJ/T136—2001第5.0.3条要求,验证规程中附录D的砂浆抗压强度换算表误差是否在规程第E.0.10条规定的范围内。

Abstract

In accordance with the 《Technical specifications for testing compressive strength of masonry mortar by penetration resistance method》JGJ/T 136-2001 section 5.0.3 requirements, Validate the error of mortar compressive strength conversion tables of Appendix D of the specification within the scope of section E.0.10 of the specification or not.

关键词

砌筑砂浆/贯入法检测/统一测强曲线/误差验证

Key words

masonry mortar/penetration resistance method/unified curve of testhlg compressive strength/error validation.