首页|某"油改气"老旧长输管道检验与适用性评价案例

某"油改气"老旧长输管道检验与适用性评价案例

Overall Inspection and Applicability Evaluation of an Old"Oil to Gas"Long-distance Pipeline

扫码查看
针对某老旧"油改气"长输管道,业主利用内检测、补强、改线、阴极保护改造、多次定期检验等多种手段,使该老旧"油改气"长输管道平稳运行8年且累计使用年限达29年.本文对该老旧"油改气"长输管道开展了全面检验和使用评价,发现长输管道定期检验规则基本满足企业对该管道安全检验与评价需求,从检验机构角度强调了资料审查和高后果区调查的重要性,建议使用单位在城镇化发展中定期排查评估杂散电流源,最后提出了下一周期应进行内检测的建议.
For an old"oil to gas"long distance pipeline,the owner used internal testing,reinforcement,route change,cathodic protection transformation,multiple periodic inspection and other means,so that the old"oil to gas"long distance pipeline has been running smoothly for 8 years and has been used for 29 years.This paper carried out a comprehensive inspection and operational evaluation of the old"oil to gas"long distance pipeline.It is found that the regular inspection rules for long-distance pipelines basically meet the needs of enterprises for safety inspection and evaluation of their pipelines.The importance of data review and investigation in high consequence areas is emphasized from the perspective of inspection institutions.It is suggested that users should regularly investigate and evaluate stray current sources in the development of urbanization.Finally,the suggestion that internal testing should be carried out in the next cycle is put forward.

Oil to gasLong distance pipelineInternal testingMaterial evaluate

高辉、刘杰、洪旭

展开 >

机械工业上海蓝亚石化设备检测所有限公司 上海 201600

华港燃气集团河间管道集输有限公司 沧州 061000

深圳中晨管道技术有限公司 深圳 518000

油改气 长输管道 内检测 材料评价

2024

中国特种设备安全
中国特种设备检测研究中心 中国锅炉水处理协会 中国特种设备检验协会

中国特种设备安全

影响因子:0.28
ISSN:1673-257X
年,卷(期):2024.40(6)