Design and Implementation of the Dynamic Functional Test Method for the Reactor Protection System of Nuclear Power Plant
In order to solve the problem that the lead lag is not tested in the traditional reactor protection system functional test,a dynamic functional test method of reactor protection system is designed.Dynamic signals are injected into the source of the logical function block and dynamic output of the functional block is monitored.Meanwhile,the same dynamic signals are modeled and applied to the logical function block in the simulation software to confirm the consistency between the measured results and the simulation results.After the above test scheme is implemented,it is found that the test results are in good agreement with the modeling and simu-lation results,which can be applied to the functional verification of the reactor protection system.
reactor protection systemdynamic function testsimulation