M310型核电机组核取样系统设计上对一回路相关容器中气体取样检测方法存在人员误吸入放射性气体造成内照射、测量结果偏差大、氢氧混合爆炸、烟囱辐射监测仪表报警等风险.本文结合核取样系统现有设计安装,通过新增含氢放射性气体取样排气路径并根据容器不同工作状态选择合理的取样排气路径、设计制作便携式氢氧测量装置两方面对一回路相关容器气体取样检测方法进行优化,优化后经现场实际应用证明效果显著.
Risk Analysis and Optimization of the Primary Circuit Related Vessel Gas Sampling Detection Method for Nuclear Power Plant
In the design of the nuclear sampling system of the M310 unit,the sampling and detection method of the gas in the primary relevant vessel has some risks,such as accidental inhalation of radioactive gas by personnel,large deviation of measurement results,explosion of hydrogen and oxygen mixture,and alarm of the chimney radiation monitoring instrument.Combined with the existing design and installation of the nuclear sampling system,this paper optimizes the gas sampling and detection method of primary related vessels by adding sampling and exhaust paths of hydrogen-containing radioactive gases,selecting reasonable sampling and exhaust paths according to different working conditions of the vessels,and designing and producing portable hydrogen and oxygen measuring devices.