首页|杂交链式反应太赫兹超表面传感器检测miRNA-92a浓度

杂交链式反应太赫兹超表面传感器检测miRNA-92a浓度

扫码查看
由于结直肠癌潜伏期长、发展缓慢,早期很难得到准确诊断.外泌体中的microRNA(简称miRNA)是包含18到22个核苷酸的非编码RNA,参与转录抑制和转录后调控,与肿瘤细胞的增殖与迁移过程息息相关.因此,可以通过检测外泌体中的miRNA浓度实现对结直肠癌的早期诊断.以太赫兹超表面传感器为检测元件,结合杂交链式反应(HCR)信号放大策略,提出一种高灵敏度检测miRNA-92a浓度的方法.实验结果表明,超表面传感器谐振频率的频移量与miRNA-92a的浓度之间具有良好的线性关系,检测灵敏度达6.26 GHz/lgCmiRNA-92a.所提方法具有快速、检出限低和灵敏度高等优点,适用于对癌症相关外泌体浓度的快速检测和疾病早期诊断.
Detection of miRNA-92a Concentration Using Terahertz Metasurface Sensors Based on Hybrid Chain Reaction
Objective The early and accurate diagnosis of colorectal cancer is difficult to perform owing to its long incubation period and slow development.MicroRNA(miRNA)in exosomes is a non-coding RNA containing 18-22 nucleotides that participate in transcriptional inhibition and post-transcriptional regulation.Thus,it is closely related to the proliferation and migration of tumor cells.Therefore,colorectal cancer can be diagnosed early by detecting the concentration of miRNA in extracellular vesicles.Methods We propose a highly sensitive method for detecting miRNA-92a concentrations using terahertz metasurface sensors as detection elements and a mixed-chain reaction(HCR)signal-amplification strategy.In our experiment,we first modified nanogold and a capture probe H0 on a metasurface sensor.Next,we deposited tested miRNAs onto the sensor.Subsequently,we deposited hybrid chains H1 and H2.Finally,we washed uncapturedmiRNAs and hybrid chains using PBS buffer.Results and Discussions In this study,a method for detecting the miRNA-92a biomarker in colorectal cancer is devised and verified.This method utilizes the capture probe H0 to bind AuNPs and modify them on a terahertz metasurface sensor.As H0 is designed for miRNA-92a,the modified sensor exhibits good specificity for miRNA-92a.As shown in Figures 7 and 8,the sensor surface is modified using hybrid chains to trigger the HCR reaction,thus forming a DNA long-chain structure and causing a significant shift in the resonant frequency of the sensor.Conclusions The experimental results show that the shift in the resonant frequency of the metasurface sensor correlates linearly with the miRNA-92a concentration,and that the maximum detection sensitivity achieved is 6.26 GHz/lgCmiRNA-92a.This method offers the advantages of rapid detection,low detection limit,and high sensitivity,thus rendering it suitable for the rapid detection of cancer-related extracellular vesicle concentrations and the early diagnosis of diseases.

terahertz spectroscopymetasurface sensorhybrid chain reactiondiagnosis of colorectal cancerexosomes microRNA

杨墨、林上君、陈洁、胡放荣

展开 >

北华航天工业学院机电工程学院,河北廊坊 065000

桂林电子科技大学电子工程与自动化学院,广西桂林 541004

太赫兹光谱技术 超表面传感器 杂交链式反应 结直肠癌诊断 外泌体microRNA

国家自然科学基金广西自然科学基金

620650052020GXNSFDA238019

2024

中国激光
中国光学学会 中科院上海光机所

中国激光

CSTPCD北大核心
影响因子:2.204
ISSN:0258-7025
年,卷(期):2024.51(15)