首页|集束皮秒拍瓦激光靶瞄准系统设计分析与实验研究

集束皮秒拍瓦激光靶瞄准系统设计分析与实验研究

扫码查看
在激光驱动的惯性约束核聚变的快点火方案中,需要将集束拍瓦皮秒激光精准引导至数十微米的金锥锥底上,并且瞄靶过程需要避免对冷冻靶预热。鉴于此,本课题组设计了一种集束皮秒拍瓦激光靶瞄准系统,使入射激光和对靶成像分离,从而实现非激光直接辐照下的近距离高精度束靶耦合。设计了识别焦斑与靶位置的程序,以减小人工识别误差,提高效率。搭建离线瞄准平台并开展了验证实验,该系统在5mm×5mm视场范围内的靶分辨率优于90。5 lp/mm(11。04 μm),重复实验的平均束靶耦合精度为4。32μm。进一步使用Zemax软件优化成像系统,优化后系统在10 mm×10 mm视场范围内的分辨率优于5 pm。此系统为惯性约束核聚变的皮秒集束激光束靶耦合提供了高精度的解决方案。
Design Analysis and Experimental Study on Target-Alignment System of Multibeam Picosecond PW Laser
Objective Inertial confinement fusion(ICF)is the primary approach for achieving controlled nuclear fusion.To enhance the efficiency of laser fusion energy and attain higher yields,Tabak proposed a fast-ignition scheme for ICF.A critical challenge in fast-ignition fusion schemes is precisely guiding multiple high-energy picosecond laser beams onto the target.Because the bottom circle of the target cone measures only tens of micrometers,an error of a few micrometers or preheating the cryogenic target will result in a failed ignition experiment.Consequently,the precision of beam-target coupling directly determines the result of the ICF experiment.This study presents a novel design for a target-alignment system for PW laser beams.The laser beams and target image are separated by a beam splitter;therefore,this design inhibits the direct laser irradiation of the cryogenic target.However,the alignment system enables high-precision beam-target coupling without direct laser irradiation,which benefits fast-ignition-scheme experiments.Methods Based on the laser-beam layout and the requirement of beam-target coupling in a fast-ignition scheme,the structure of the target-alignment system of picosecond PW laser beams was designed in this study;a schematic diagram of the system is shown in Figure 1.Based on the actual situation of beam-target coupling,the target-aiming system was constructed on an offline experimental platform;subsequently,the resolution test target was used to verify the imaging resolution of the system.A beam-target coupling experiment was conducted,and the beam-target coupling accuracy of this system was measured through multiple experiments.The Zemax software was used to optimize the imaging simulation of the target,and the resolution experiment was simulated and analyzed.Subsequently,the factor contributing to the low resolution was determined,and the imaging mirror set was designed and optimized to further improve the imaging quality.Finally,a program was designed to identify the positions of the target and focal spot in real time,thus improving the accuracy and efficiency of the beam-target coupling.Results and discussions The resolution-verification experiment performed on this system shows that the initial plain plate splitter introduces severe aberration[Figs.4(a)and(b)],which was solved after performing optimization using a cube plate splitter[Figs.4(c)and(d)].Further use of aspheric mirror improves the resolution,and the final resolution of the target in the experiment is 90.5 lp/mm(11.04 μm)in a 5 mm×5 mm field-of-view[Figs.4(e)and(f)].Figure 5 shows the beam-target coupling process using this system.The results of multiple experiments show that the error in the x-direction is slightly larger than that in the y-direction,which may be caused by the system asymmetry.Finally,the average position error of the beam-target coupling system is 4.32 μm(Table 1),which is lower than that of the existing beam-target coupling scheme and satisfies the high-precision beam-target coupling requirements.Zemax was used to verify the experimental results of target imaging,and the simulation analysis shows that the lens can be further optimized.Therefore,the lens was optimized,and the results are shown in Figure 7.The MTF(modulation transfer function)curve and simulated imaging results indicate that the resolution is greater than 5 μm in a 10 mmX 10 mm field-of-view.Finally,a real-time recognition program was designed to identify the positions of the focal spot and target(Fig.2),thus reducing the error of subjective judgment and improving the efficiency of beam-target coupling.Currently,this system can be further optimized.The mirror set optimized using Zemax has neither been processed nor adjusted,and further measurements of the target-imaging effect will be performed in subsequent studies.Conclusions This paper introduces an innovative target-alignment system for picosecond PW laser beams.To satisfy the requirements of cryogenic target coupling in an ICF fast-ignition experiment,beam-target coupling was realized via non-laser direct irradiation,which offers high levels of resolution,precision,and efficiency.An image-recognition program based on beam-target coupling was developed to avoid errors caused by manual judgment and to improve the efficiency of beam-target coupling.An offline verification experiment was performed,where the target resolution is 90.5 lp/mm(11.04 μm)in a 5 mm×5 mm field-of-view.Multiple experiments show that the average position error of beam-target coupling is 4.32 μm,which is lower than that of the existing remote-observation beam-target coupling scheme,which features tens of microns of error.Optical optimization was performed via simulation.After the optimization,the imaging resolution of the target is expected to be greater than 5 μm in a 5 mm×5 mm field-of-view.This system provides a high-precision solution for the picosecond laser-beam coupling of a cryogenic target and presents wide application prospects in future large-scale picosecond laser-beam experiments.

inertial confinement fusionbeam-target couplinglaserbeam alignmentsensor

康海涛、朱坪、张栋俊、姚修宇、易友建、李兆良、童妙妍、华能、乔战峰、孙明营、栗建兴、朱健强

展开 >

西安交通大学物理学院,陕西省量子信息与光电量子器件重点实验室,教育部物质非平衡合成与调控重点实验室,陕西西安 710049

中国科学院上海光学精密机械研究所,高功率激光物理联合实验室,上海 201800

中国科学院大学材料与光电研究中心,北京 100049

惯性约束核聚变 束靶耦合技术 激光器 光束引导 传感器

2024

中国激光
中国光学学会 中科院上海光机所

中国激光

CSTPCD北大核心
影响因子:2.204
ISSN:0258-7025
年,卷(期):2024.51(21)