首页|浅析某雷达末级行波管故障的检修调试方法

浅析某雷达末级行波管故障的检修调试方法

扫码查看
末级行波管是某雷达Ⅱ波段发射机的核心器件,在发生故障需要更换并调试时,需要对电路进行全面检查。特别是在遇到多路同时报警的复杂情况下,必须确保外围电路正常,才能更换新管并进行加电调试。基于此,本文详细阐述了某雷达Ⅱ波段发射机出现多路同时报警时更换行波管的检修步骤,深入分析了发生故障的原因,并总结了检修及调试过程中的注意事项。
Analysis on the Fault Detection and Debugging Method of a Radar Final Stage TWT
The final stage of the traveling wave tube is the core component of a radar II.band transmitter,and the circuit should be fully inspected when it needs to be replaced and debugged in the event of a failure.Especially in the complex case of multiple simultaneous alarms,it is necessary to ensure that the peripheral circuit is normal before replacing the new tube and powering up the debugging.This paper elaborates the maintenance steps of replacing the traveling wave tube when there are multiple simultaneous alarms in a radar II.band transmitter,analyzes the possible causes of the failure,and summarizes the precautions in the maintenance and debugging process.

TWT(Travelling Wave Tube)multi-channel alarmmaintenance proceduremultiple analysis

宋林涛、张新锋、姚远、祝梁

展开 >

中国人民解放军63889部队,河南 焦作 454750

行波管 多路报警 检修步骤 复盘分析

2024

中国科技纵横
中国民营科技促进会

中国科技纵横

影响因子:0.102
ISSN:1671-2064
年,卷(期):2024.(21)