中国科学:技术科学(英文版)2024,Vol.67Issue(4) :1077-1093.DOI:10.1007/s11431-023-2498-9

Energy and exergy analyses and optimizations for two-stage TEC driven by two-stage TEG with Thomson effect

CHEN LinGen GE YanLin FENG HuiJun REN TingTing
中国科学:技术科学(英文版)2024,Vol.67Issue(4) :1077-1093.DOI:10.1007/s11431-023-2498-9

Energy and exergy analyses and optimizations for two-stage TEC driven by two-stage TEG with Thomson effect

CHEN LinGen 1GE YanLin 1FENG HuiJun 1REN TingTing1
扫码查看

作者信息

  • 1. Institute of Thermal Science and Power Engineering,Wuhan Institute of Technology,Wuhan 430205,China;Hubei Provincial Engineering Technology Research Center of Green Chemical Equipment,Wuhan 430205,China;School of Mechanical & Electrical Engineering,Wuhan Institute of Technology Wuhan 430205,China
  • 折叠

Abstract

Based on the non-equilibrium thermodynamics and energy and exergy analyses,a thermodynamic model of two-stage thermo-electric(TE)cooler(TTEC)driven by two-stage TE generator(TTEG)(TTEG-TTEC)combined TE device is established with involving Thomson effect by fitting method of variable physical parameters of TE materials.Taking total number of TE elements as constraint,influences of number distributions of TE elements on three device performance indictors,that is,cooling load,maximum COP and maximum exergetic efficiency,are analyzed.Three number distributions of TE elements are optimized with three maximum performance indictors as the objectives,respectively.Influences of hot-junction temperature of TTEG and cold-junction temperature of TTEC on optimization results are analyzed,and difference between optimization results corresponding to three performance indicators are studied.Optimal performance intervals and optimal variable intervals are provided.Influ-ences of Thomson effect on three general performance indicators,three optimal performance indicators and optimal variables are comparatively discussed.Thomson effect reduces three general performance indicators and three optimal performance indicators of device.When hot-and cold-junction temperatures of TTEG and TTEC are 450,305,325 and 295 K,respectively,Thomson effect reduced maximum cooling load,maximum COP and maximum exergetic efficiency from 9.528 W,9.043×10-2 and 2.552%to 6.651 W,6.286x1 0-2 and 1.752%,respectively.

Key words

non-equilibrium thermodynamics/cooling load/COP/exergetic efficiency/combined thermoelectric device/performance optimization

引用本文复制引用

基金项目

国家自然科学基金(52171317)

出版年

2024
中国科学:技术科学(英文版)
中国科学院

中国科学:技术科学(英文版)

CSTPCDEI
影响因子:1.056
ISSN:1674-7321
参考文献量96
段落导航相关论文