扫码查看
该研究通过优化色谱条件及方法学考察建立了一种离子色谱技术同时测定饮用水中痕量铬(六价)、草甘膦(GLY)、高氯酸盐及7种常规阴离子(F-、Cl-、NO2-、Br、NO3-、SO42-、PO43-)含量的方法,并采用该方法对饮用水中的10种目标物进行测定。结果表明,最优色谱条件为:以DionexTMIonPacTMAS20为分析柱,DionexTM IonPacTM AG20为保护柱,KOH为淋洗液,梯度洗脱,流速为1。0 mL/min,抑制器为ADRS600(4 mm),抑制电流为138 mA,柱温为30 ℃,检测器温度为35 ℃,进样量为500 μL。痕量铬(六价)、GLY、高氯酸盐及7种常规阴离子在各自的线性范围内具有良好的线性关系(R2>0。999),检出限(LOD)和定量限(LOQ)均在0。079~1。145 μg/L和0。263~3。817 μg/L之间;各物质之间的分离度>1。5;重复性、稳定性试验结果的相对标准偏差(RSD)均≤3。38%;以饮用水为本底进行加标回收试验,各物质的平均加标回收率为90。9%~98。1%,加标回收率试验及精密度试验结果的RSD分别为0。67%~4。33%、0。12%~3。33%。综上,该方法适用于饮用水中痕量铬(六价)、GLY、高氯酸盐及7种常规阴离子的同时测定。
Simultaneous determination of chromium(hexavalent),glyphosate,perchlorate and 7 anions content in drinking water by ion chromatography
An ion chromatography method for simultaneous determination of trace chromium(hexavalent),glyphosate(GLY),perchlorate and 7 con-ventional anions(F-,Cl-,NO2-,Br,NO3-,SO42-,PO43)in drinking water by optimizing chromatographic conditions and methodological investigation was established,and the 10 targets in drinking water was determined.The results showed that the optimized chromatographic conditions were:Dionex IonPacTMAS20 as analytical column,Dionex IonPacTMAG20 as protection column,KOH as eluent,gradient elution,flow rate 1.0 ml/min,suppressor ADRS600(4 mm),suppression current 138 mA,column temperature 30 ℃,detector temperature 35 ℃,and sample volume 500 μL.Trace chromium(hexavalent),GLY,perchlorate and 7 conventional anions had good linear relationships in their respective linear ranges(R2>0.999).The limits of de-tection(LOD)and limits of quantification(LOQ)of each substance were 0.079-1.145 μg/L and 0.263-3.817 μg/L.The resolution between each sub-stance was>1.5.The relative standard deviation(RSD)of the reproducibility and stability test results were both ≤ 3.38%.The spiked recovery rate tests with drinking water as the substrate,the average recovery rates of each substance were 90.0%-99.3%,and the RSD of spiked recovery rate and preci-sion tests were 0.67%-4.33%and 0.12%-3.33%,respectively.In summary,the method was suitable for simultaneous determination of trace chromium(hexavalent),GLY,perchlorate and 7 common anions in drinking water.

drinking waterchromium(hexavalent)glyphosateanionion chromatographysuppressor conductivity

周亮、吴国权、陈洁

展开 >

重庆市开州区疾病预防控制中心,重庆 405499

赛默飞世尔科技(中国)有限公司,广东 广州 510800

饮用水 铬(六价) 草甘膦 阴离子 离子色谱法 抑制电导

2024

中国酿造
中国调味品协会 北京食品科学研究院

中国酿造

CSTPCD北大核心
影响因子:0.759
ISSN:0254-5071
年,卷(期):2024.43(12)