首页|Analysis of the Erosion-Corrosion Mechanism of the Air Cooler in a Hydrocracking Unit:A Numerical and Experimental Study

Analysis of the Erosion-Corrosion Mechanism of the Air Cooler in a Hydrocracking Unit:A Numerical and Experimental Study

扫码查看
Corrosion leakages often occur in the air cooler of a hydrocracking unit,with the failure sites mainly located in the entrance area of the tubes.An analysis of the macroscopic morphology and corrosion products confirmed that the damage was caused by erosion-corrosion(E-C).Numerical and experimental methods were applied to investigate the E-C mechanism in the air cooler.Computational fluid dynamics(CFD)was used to calculate the hydrodynamic parameters of the air cooler.The results showed that there was a biased flow in the air cooler,which led to a significant increase in velocity,turbulent kinetic energy and wall shear within 0.2 m of the tube entrance.A visualization experiment was then performed to determine the principles of migration and transformation of multiphase flow in the air cooler tubes.Various flow patterns(pure droplet flow,mist flow,and annular flow)and their evolutionary processes were clearly depicted experimentally.The initiation mechanism and processes leading to the development of E-C in the air cooler were also determined.This study provided a comprehensive explanation for the E-C failures that occur in air coolers during operation.

air coolerhydrocracking uniterosion-corrosionsimulationvisualization experimentmultiphase flow

Su Guoqing、Li Yan、Guo Hongli、Zhang Jianwen

展开 >

College of Mechanical and Electrical Engineering,Beijing University of Chemical Technology,Beijing 100029,China

国家重点研发计划Beijing University of Chemical Technology Interdisciplinary Program

2021YFB3301100XK2023-07

2024

中国炼油与石油化工(英文版)
中国石化集团石油化工科学研究院

中国炼油与石油化工(英文版)

影响因子:1.199
ISSN:1008-6234
年,卷(期):2024.26(1)
  • 28