首页|A novel simulation method to evaluate the collection performance of a monolithic active pixel sensor

A novel simulation method to evaluate the collection performance of a monolithic active pixel sensor

扫码查看
A novel simulation method is presented in this paper to evaluate the collection performance of monolithic active pixel sensor (MAPS) devices for minimum ionizing particle tracking.A simplified 3D matrix pixel structure is built using the computer aided design software Sentaurus.The virtual device is then divided into hundreds of parts and an independent customized X photon model is involved in each part to simulate the conditions under 55Fe radiation.After data processing and analysis,charge collection efficiency,collection time and diffusion conditions can be estimated in detail.In order to verify the reliability of the method,comparisons are made between the simulations and experiments.Although there are some defects,it can be concluded that the proposed idea is a feasible method for the evaluation of the MAPS collection performance.

MAPScharge collectionevaluationsimulation

FU Min、TANG Zhen-An

展开 >

School of Electronic Science and Technology, Dalian University of Technology, Dalian 116024, China

France-China Particle Physics Laboratory (FCPPL) and China Scholarship Council (CSC)

2011

中国物理C(英文版)
中国物理学会 中国科学院高能物理研究所 中国科学院近代物理研究所

中国物理C(英文版)

CSTPCDCSCDSCI
影响因子:0.347
ISSN:1674-1137
年,卷(期):2011.35(10)
  • 22