电子束杀灭新型冠状病毒的效果验证
Verification of killing effect of electron beam on SARS-CoV-2
杨孝祥 1钱胜兵 1刘威龙 1廖明凤 1曾志强 1蒋国斌 1余道坚 2方泽坤 3张明霞1
作者信息
- 1. 深圳市第三人民医院,广东深圳 518112
- 2. 深圳海关动植物检验检疫技术中心
- 3. 中广核金沃科技有限公司
- 折叠
摘要
目的 验证电子束对新型冠状病毒的杀灭能力,为其实际消毒应用提供依据.方法 采用Vero细胞培养法制取病毒悬液,应用不同辐照剂量的电子束对染毒滤纸片照射,检测存活病毒滴度和回收液上清液中的新型冠状病毒核酸,以核酸检测的结果、细胞病变效应和病毒半数组织感染量(TCID50)评价杀灭效果.结果 在环境温度为-20~20℃条件下,辐照剂量为5 kGy,对染毒纸片上新型冠状病毒杀灭对数值>4.0.-80℃条件下,辐照剂量9 kGy,对染毒纸片上新型冠状病毒杀灭对数值>4.0.结论 温度越低,新型冠状病毒对电子束的耐受剂量越高.
Abstract
Objective To verify the inactivation capability of electron beam against SARS-CoV-2,and to provide a basis for application.Methods Vero cells were cultured to produce SARS-CoV-2 viral suspension.The viral suspension was dorped on filter paper then irradiated with various doses of electron beam.The titer of the surviving virus and the nucleic acid of SARS-CoV-2 in the recovered supernatant was detected.The killing effect was estimated by nucleic acid test,cytopathic effect and the half tissue infection amount of the virus(TCID50).Results At-20℃to 20℃,the killing logarithm value of 5 kGy irradiation dose for SARS-CoV-2 was>4.0.At-80℃,the killing logarithm value of 9 kGy irradiation dose for SARS-CoV-2 were>4.0.Conclusion For the lower temperature,the tolerance dose of SARS-CoV-2 to the electron beam is higher.
关键词
新型冠状病毒/电子束辐照/杀灭效果/辐照剂量Key words
SARS-CoV-2/electron beam irradiation/killing effect/irradiation dose引用本文复制引用
基金项目
海关总署科研项目(2021HK167)
国防科工局项目(HNKF2021001)
广东省重点领域研发计划项目(2022B1111010003)
广东省科技计划项目(2021B1212030010)
深圳市科技计划项目(JSGG20210901145407021)
出版年