The Observation and Analysis of the Effect of Automatic Peritoneal Dialysis Instrument in Peritoneal Dialysis Patients
Objective:To analyze the effect of automatic peritoneal dialysis instrument in patients undergoing peritoneal dialysis.Methods:From January 2021 to January 2022,60 patients with peritoneal dialysis were randomly selected and classified according to the dialysis mode of patients,that is,experiment group and controlgroup.The number of patients in each group was 30.The control group as a whole received continuous circulating peritoneal dialysis,and the experimental group as a whole received tidal peritoneal dialysis,and the effect was compared.Results:Before treatment,the experimental group's urea nitrogen(BUN),serum creatinine(Scr),blood uric acid(UA),interleukin-6(IL-6),IL-8,and tumor necrosis factor were measured-α(TNF)-α、C-reactive protein(CRP)showed no difference compared to the control group,P>0.05.After treatment,the blood urea nitrogen(BUN),serum creatinine(Scr),blood uric acid(UA),interleukin-6(IL-6),IL-8 and tumor necrosis factor in the experimental group-α(TNF-α),C-reactive protein(CRP)was significantly lower than that of the control group(P<0.05).There was no difference in complications between the experimental group and the control group after treatment(P>0.05).Conclusion:The use of automatic peritoneal dialysis instrument in the treatment of clinical peritoneal dialysis patients can reduce the inflammatory index,improve the renal function of patients,improve the curative effect,and has high safety.The choice of the method depends on the actual situation of patients.