首页|输液器自动止液性能测试方法的研究

输液器自动止液性能测试方法的研究

扫码查看
目的:通过搭建临床输液模型,研究输液器的止液性能,为建立止液性能试验方法评价提供参考依据.方法:建立临床输液模型,用不同类型静脉输液药液(酸性、碱性、脂溶性、高渗、高黏度、高密度等药物)考察输液器的自动止液性能.结果:8批次不同厂家的输液器进行自动止液性能测试,输液完毕后产品均能达到自动止液效果.结论:通过构建的输液模型,选取氯化钠溶液作为试验介质进行止液性能测试,其测试装置和试验方法可满足试验要求.
Study on the Test Method of Automatic Liquid-Stop Performance of Infusion Set
Objective:To study the hemostatic performance of infusion set by setting up clinical infusion model,and to provide reference for the evaluation of test method of hemostatic performance.Methods:To establish a clinical model of infusion,and use different kinds of drug infusion(acid,basic,fat-soluble,hypertonic,high viscosity,high density,etc.)to investigate the performance of automatic infusion device.Results:8 lots of infusion sets from different manufacturers were tested for automatic liquid stop performance,and the products could achieve automatic liquid stop effect after infusion.Conclusion:Through the established infusion model,sodium chloride solution was selected as the medium to test the liquid stopping performance.The testing device and method can meet the test requirements.

infusionautomatic liquid-stop performanceinfusion model

吴欢、董璨、胡嘉昊、周琦、郭强、张仕林、李玲、艾鸣哲、董慧

展开 >

湖北省医疗器械质量监督检验研究院(湖北 武汉 430075)

输液器 自动止液 输液模型

2024

中国医疗器械信息
中国医疗器械行业协会

中国医疗器械信息

影响因子:0.375
ISSN:1006-6586
年,卷(期):2024.30(5)
  • 7