Study on the Safety of Self Service Separated Nebulizer Used in Cervical Spondylosis Patients During the Perioperative Period
Objective:To explore the safety of the application of self-service partition atomizer in cervical spine patients during the perioperative period.Methods:100 patients with cervical spondylosis who visited the First Affiliated Hospital of Nanchang University from January 2022 to June 2022 were selected and randomly divided into the control group(n=50)and the observation group(n=50)according to the order of admission.They were treated with conventional atomizer inhalation and self-help separated atomizer in turn.The incidence of postoperative complications,patient cooperation,incidence of adverse reactions and patient satisfaction were compared between the two groups.Results:Compared with the control group,the incidence of complications and adverse reactions after treatment in the observation group were lower and the difference was significant(P<0.05);The cooperation and satisfaction of the observation group were significantly higher than those of the control group,and the difference was statistically significant(P<0.05).Conclusion:The use of self-service partition atomizers in cervical spine patients during the perioperative period can reduce the incidence of complications,improve patient coordination,and have fewer adverse reactions,resulting in higher patient satisfaction.