首页|碳离子治疗系统大功率设备浪涌与脉冲群抗扰度现场测试方法研究

碳离子治疗系统大功率设备浪涌与脉冲群抗扰度现场测试方法研究

High-Power Equipment of Carbon Ion Therapy System Surge and Pulse Group Immunity Research on Field Test Methods

扫码查看
电源辅助系统为碳离子加速器控制系统的关键子系统,电源辅助系统通过控制电源输出电流来控制磁铁磁场以实现对粒子束的精准控制,进而影响束流的性能,在临床治疗中直接关乎患者的诊疗效果和生命安全.因此,碳离子治疗系统大功率的电源机柜设备对碳离子治疗系统的安全至关重要.根据原食品药品监督管理总局颁布的《质子/碳离子治疗系统技术审查指导原则》,与碳离子治疗系统基本性能直接相关的子系统、有源部件、辅助设备等电磁兼容测试必须执行YY0505-2012的要求.新版电磁兼容标准YY9706.102-2021于2023年5月1日实施.
The magnet power control system is the key subsystem of the carbon ion accelerator control treatment system.The magnet power control system controls the magnetic field by controlling the magnet current so as to restrict the particles and then affect the beam performance.In clinical treatment,it is directly related to the diagnosis and treatment effect and life safety of patients.Carbon ion therapy system High-power power cabinet equipment is critical to the safety of carbon ion therapy system,according to the CFDA issued"Guidelines for technical review of proton/carbon ion therapy systems",The electromagnetic compatibility test of subsystems,active components,auxiliary equipment,etc.directly related to the basic performance of carbon ion therapy system must implement the requirements of YY0505-2012,and the new version of the electromagnetic compatibility standard YY9706.102-2021 will be implemented on May 1,2023.

carbon ion therapy systemdifferential mode couplingcommon-mode couplingfield test

郭虎、申彦峰、杨成乐、陈晓明

展开 >

甘肃省器械检验检测所 (甘肃 兰州 730000)

兰州科近泰基新技术有限公司 (甘肃 兰州 730000)

碳离子治疗系统 差模耦合 共模耦合 现场测试

2024

中国医疗器械信息
中国医疗器械行业协会

中国医疗器械信息

影响因子:0.375
ISSN:1006-6586
年,卷(期):2024.30(13)
  • 3