首页|GB 9706.202-2021《医用电气设备 第2-2部分:高频手术设备及高频附件的基本安全和基本性能专用要求》主要条款解读

GB 9706.202-2021《医用电气设备 第2-2部分:高频手术设备及高频附件的基本安全和基本性能专用要求》主要条款解读

扫码查看
阐述GB 9706.202-2021《医用电气设备第2-2部分:高频手术设备及高频手术附件的基本安全和基本性能专用要求》中高频手术附件的条款解读.重点对高频电解质强度中的预处理、高频泄漏、高频介电强度、工频介电强度条款进行了详细解读.
Interpretation Main Clause of the Standard GB 9706.202-2021 Medical Electrical Equipment-Part 2-2:Particular Requirements for the Basic Safety and Essential Performance of High Frequency Surgical Equipment and High Frequency Surgical Accessories
The article elaborates the meaning of the issue of GB 9706.202-2021"Medical electrical equipment—Part 2-2:Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories."It clarifies the implications of some main provisions,for example the Preconditioning and HF leakage and HF dielectric strength,mains frequency dielectric strength,and etc.

HF surgical accessoryactive electrode insulationHF leakageHF leakage currentmains frequency dielectric strength

左鹏飞、马小建、魏胜

展开 >

深圳迈瑞生物医疗电子股份有限公司 (广东 深圳 518057)

杭州迈瑞医疗科技有限公司 (浙江 杭州 311501)

高频附件 手术附件绝缘 高频泄漏 高频介电强度 工频介电强度

2024

中国医疗器械信息
中国医疗器械行业协会

中国医疗器械信息

影响因子:0.375
ISSN:1006-6586
年,卷(期):2024.30(15)