目的:分析Sysmex BM6010C生化分析仪对肝功能指标检测中的诊断效果.方法:选择2021年1月~2023年7月在本单位进行肝功能指标监测的60例受检者作为本次的研究对象,将30例健康体检者作为对照组,30例肝病患者作为观察组,分析Sysmex BM6010C生化分析仪检测后的肝功能指标情况.结果:两组的胆碱酯酶、丙氨酸转氨酶、白蛋白、直接胆红素、总胆红素、γ-谷氨酰转肽酶、天冬氨酸转氨酶对比差异存在统计学意义(P<0.05),其中,与对照组相比,观察组的胆碱酯酶、白蛋白指标更低对照组,且观察组的丙氨酸转氨酶、直接胆红素、总胆红素、γ-谷氨酰转肽酶和天冬氨酸转氨酶更高对照组,观察组的血浆黏度水平高于对照组,组间的对比差异有统计学意义(P<0.05).在重症肝炎和慢性肝炎的分析中,重症肝炎患者的胆碱酯酶和白蛋白比慢性肝炎患者更低,两组之间的比较差异有显著的统计学意义(P<0.05).结论:将Sysmex BM6010C生化分析仪用于对多项肝功能指标的检测中,能明显和健康人群形成差异,且肝功能指标会随着病情的进展而对应发生改变,能为临床医师在疾病治疗方案的制定、预后恢复效果判断等提供可靠的参考依据.
The Diagnostic Effect of Sysmex BM6010C Biochemical Analyzer on the Detection of Liver Function Indexes
Objective:To analyze the diagnostic effect of Sysmex BM6010C biochemical analyzer on liver function index.Methods:60 subjects who were monitored for liver function indexes in our unit from January 2021 to July 2023 were selected as the study objects,30 healthy subjects were selected as the control group and 30 patients with liver disease were selected as the observation group.The liver function indexes detected by Sysmex BM6010C biochemical analyzer were analyzed.Results:There were statistically significant differences in cholinesterase(ChE),alanine aminotransferase(ALT),albumin(PA),direct bilirubin(DBIL),total bilirubin(TBIL),γ-glutamyl transpeptidase(GCT)and aspartate aminotransferase(AST)between the two groups(P<0.05).The level of plasma viscosity in the observation group was higher than that in the control group with lower cholinesterase and albumin indices and higher alanine aminotransferase,direct bilirubin,total bilirubin,γ-glutamyl transpeptidase and aspartate aminotransferase,and the difference between the two groups was statistically significant(P<0.05).In the analysis of severe liver disease and chronic liver disease,the comparison difference between severe hepatitis and chronic liver disease group with lower cholinesterase and albumin was statistically significant(P<0.05).Conclusion:The use of Sysmex BM6010C biochemical analyzer in the detection of multiple liver function indicators can significantly differ from healthy people,and the liver function indicators will change correspondingly with the progression of the disease,which can provide a reliable reference for clinicians in the formulation of disease treatment plans and the judgment of prognosis and recovery effect.

biochemical analyzerliver function indexdiagnostic effectliver disease

刘小芳、付莲花、周哲明

展开 >

江西省宜春市中心血站(江西 宜春 336000)

江西省宜春市第三人民医院(江西 宜春 336000)

生化分析仪 肝功能指标 诊断效果 肝脏疾病

2024

中国医疗器械信息
中国医疗器械行业协会

中国医疗器械信息

影响因子:0.375
ISSN:1006-6586
年,卷(期):2024.30(17)