首页|多参数监护仪年度质控探讨

多参数监护仪年度质控探讨

扫码查看
目的:增进本院医工人员对多参数监护仪的了解,提高多参数监护仪的准确性、有效性和安全性.方法:回顾2019年度对本院多品牌多参数监护仪的有针对性、计划性的年度质控管理,具体措施包括配置专项的质控人员,运用FLUKE等专业质控仪器,检测多参数监护仪的各项指标,结合临床医务工作者的需要,及时整改质控中不合格的设备,优化质控方案,从而降低不合格率.结果:截至2019年11月底,本院已完成质控监护仪172台,其中,156台达到合格标准,合格率为90.6%.再对检测不合格监护仪进行维修,并进行再次质控,总体合格率上升至97.6%,提高了7%,质控管理后设备合格率明显提高.结论:通过年度的质控项目,保证医疗设备尤其是生命支持类设备的安全可靠性,根据存在的问题及时改进质控方案,提升监护仪的质量控制.与此同时,也促进了医工处和临床医护人员的沟通与交流,使多参数监护更好地服务于临床和患者.
Discussion on Annual Quality Control of Multi Parameter Monitor
Objective:To enhance the understanding of multi-parameter monitors among medical staffin our hospital and improve the accuracy,effectiveness and safety of multi-parameter monitors.Methods:Review of the targeted and planned annual quality control management of our hospital's multi-brand and multi-parameter monitors in 2019.The specific measures included assigning dedicated quality control personnel;Using FLUKE and other professional quality control instruments to test various indicators of multi-parameter monitors;In accordance with the needs of clinical medical workers,timely rectify unqualified equipment in quality control;Optimizing quality control solutions to reduce failure rates.Results:As of the end of November 2019,our hospital had completed the quality control of 172 monitors,of which 156 met the qualified standards,with a qualified rate of 90.6%.The unqualified monitors were then repaired and re-quality controlled,and the overall qualified rate rose to 97.6%,an increase of 7%.The qualified rate of equipment was significantly improved after quality control management.Conclusion:Through annual quality control projects,the safety and reliability of medical equipment,especially life support equipment,are ensured.Quality control plans are improved in a timely manner based on existing problems,and the quality control of monitors is enhanced.At the same time,it also promotes communication and exchange between the medical department and clinical medical staff,making multi parameter monitoring better serve clinical and patient needs.

multi parameter monitorquality control planquality control resultsquality control analysis

刘安琪

展开 >

无锡市中医医院医学工程处 (江苏 无锡 214400)

多参数监护仪 质控方案 质控结果 质控分析

2024

中国医疗器械信息
中国医疗器械行业协会

中国医疗器械信息

影响因子:0.375
ISSN:1006-6586
年,卷(期):2024.30(17)