目的:研究可视化径道检视仪联合ATP生物荧光检测法在腔镜器械清洗质量控制中的应用.方法:选取2022年3月~2023年10月本院腔镜器械进行清洗质量控制300件,按检测方式不同随机分为试验组(可视化径道检视仪)、对照组(ATP生物荧光检测法)、联合组(可视化径道检视仪联合ATP生物荧光检测法),各组100件.比较三组的应用效果.结果:三组的腔镜器械一般情况相比,P>0.05;联合组(25.00%)比试验组(7.00%)、对照组(11.00%)的腔镜器械清洗不合格率更高,P<0.05;联合组比试验组、对照组的器械清洗费用更低,P<0.05.结论:腔镜器械清洗质量控制实施可视化径道检视仪联合ATP生物荧光检测法更具备可靠性,且检测费用低,更适合于日常检测.
To Explore the Application of Visual Path Viewer Combined with ATP Bioluminescence Detection in the Quality Control of Laparoscopic Instrument Cleaning
Objective:To study the application of visual path viewer combined with ATP bioluminescence detection method in the quality control of laparoscopic instrument cleaning.Methods:A total of 300 laparoscopic instruments for cleaning quality control in our hospital from March 2022 to October 2023 were selected and randomly divided into experimental group(visual path viewer),control group(ATP biolumineourofluorescence detection method),and joint group(visual path viewer combined with ATP biolumineourofluorescence detection method)according to different detection methods,with 100 pieces in each group.The application effects of the three groups were compared.Results:The general conditions of laparoscopic instruments in the three groups were compared(P>0.05).The failure rate of laparoscopic instrument cleaning in joint group(25.00%)was higher than that in experimental group(7.00%)and control group(11.00%)(P<0.05).The cleaning cost of joint group was lower than that of experimental group and control group(P<0.05).Conclusion:The visual path viewer combined with ATP bioluminescence detection method for the quality control of laparoscopic instrument cleaning is more reliable,and the detection cost is low.It is more suitable for daily detection.

visual path viewerATP bioluminescence detection methodcleaning of endoscopic instrumentsquality controlapplication

任凤英、刘文娟

展开 >

新疆医科大学第二附属医院消毒供应室 (新疆 乌鲁木齐 830028)

新疆医科大学第二附属医院手术麻醉科 (新疆 乌鲁木齐 830028)

可视化径道检视仪 ATP生物荧光检测法 腔镜器械清洗 质量控制 应用

2024

中国医疗器械信息
中国医疗器械行业协会

中国医疗器械信息

影响因子:0.375
ISSN:1006-6586
年,卷(期):2024.30(18)