中国医学影像技术2024,Vol.40Issue(1) :93-97.DOI:10.13929/j.issn.1003-3289.2024.01.018

体素内不相干运动成像定量评估慢性移植肾功能不全

Intravoxel incoherent motion for quantitative evaluating chronic allograft dysfunction

王盼 李向南 郑鑫 胡小鹏 张琛 蒋涛 李敏
中国医学影像技术2024,Vol.40Issue(1) :93-97.DOI:10.13929/j.issn.1003-3289.2024.01.018

体素内不相干运动成像定量评估慢性移植肾功能不全

Intravoxel incoherent motion for quantitative evaluating chronic allograft dysfunction

王盼 1李向南 2郑鑫 3胡小鹏 4张琛 5蒋涛 2李敏2
扫码查看

作者信息

  • 1. 北京市房山区第一医院放射科,北京 102400
  • 2. 首都医科大学附属北京朝阳医院放射科,北京 100020
  • 3. 首都医科大学附属北京佑安医院泌尿外科,北京 100069
  • 4. 首都医科大学附属北京朝阳医院泌尿外科,北京 100020
  • 5. 西门子医疗有限公司磁共振科研合作部,北京 100102
  • 折叠

摘要

目的 观察弥散加权成像体素内不相干运动(IVIM)定量评估慢性移植肾功能不全(CAD)的价值.方法 前瞻性纳入104例CAD患者,根据估算肾功能受损程度分为CAD 1、2、3组(n=11、61、32);另以36名健康志愿者为对照组.比较组间及组内肾皮、髓质IVIM参数真性弥散系数(D值)、微循环灌注弥散系数(D*值)及灌注分数(f值),评价IVIM参数诊断CAD的价值.结果 移植肾皮质D值在各CAD组均低于对照组(P均<0.05),且在1组、2组、3组依序减低(P均<0.05);CAD 2组、3组移植肾髓质D值均低于对照组(P均<0.05).各CAD组移植肾皮质D*值均低于对照组(P均<0.05),CAD 2组、3组肾髓质D*值均低于对照组(P均<0.05).CAD 2组、3组移植肾皮质、髓质f值均低于对照组(P均<0.05),CAD 3组移植肾皮质f值低于1组及2组(P均<0.05).各组肾皮质D值、D*值、f值均高于髓质(P均<0.05).皮质IVIM联合模型诊断CAD的曲线下面积(AUC)为0.96,优于D*值及f值(AUC=0.74、0.83,P均<0.05)而与D值(AUC=0.94)差异无统计学意义(P=0.32).髓质IVIM联合模型诊断CAD的AUC为0.91,优于D值、D*值及f值(AUC=0.80、0.67、0.80,P均<0.05).结论 IVIM参数可定量评估CAD.

Abstract

Objective To observe the value of diffusion weighted imaging intravoxel incoherent motion(IVIM)for quantitative evaluating chronic allograft dysfunction(CAD).Methods Totally 104 CAD patients were prospectively enrolled and were assigned into CAD 1,2 and 3 groups(n=11,61,32)based on impairment severity of estimated renal function,and 36 healthy volunteers were enrolled as control group.The true diffusion coefficient(D value),microcirculation perfusion diffusion coefficient(D*value)and perfusion score(f value)of renal cortex and medulla IVIM parameters were compared among groups and within groups to assess the value of IVIM parameters for diagnosing CAD.Results The D value of transplanted renal cortex in all CAD groups were lower than that in control group(all P<0.05),which decreased among CAD 1,2 and 3 groups(all P<0.05).The D value of transplanted kidney medulla in CAD 2 and 3 groups were lower than that in control group(both P<0.05).The D*values of transplanted renal cortex in all CAD groups were lower than that in control group,while of renal medulla in CAD 2 and 3 groups were lower than that in control group(both P<0.05).The f values of cortex and medulla in CAD 2 and 3 groups were lower than those in control group(all P<0.05),while of cortex in CAD 3 group was lower than that in CAD 1 and 2 groups(both P<0.05).The area under the curve(AUC)of cortical IVIM combined model for diagnosing CAD was 0.96,better than the D*value and f value(AUC=0.74,0.83,P<0.05)but not significantly different with that of the D value(AUC=0.94,P=0.32).AUC of medullary IVIM combined model for diagnosing CAD was 0.91,better than that of D,D*and f value(AUC=0.80,0.67 and 0.80,all P<0.05).Conclusion IVIM parameters could be used to quantitatively evaluate CAD.

关键词

肾移植/肾功能不全,慢性/磁共振成像/前瞻性研究

Key words

kidney transplantation/renal insufficiency,chronic/magnetic resonance imaging/prospective studies

引用本文复制引用

出版年

2024
中国医学影像技术
中国科学院声学研究所

中国医学影像技术

CSTPCD北大核心
影响因子:0.763
ISSN:1003-3289
被引量1
参考文献量7
段落导航相关论文