Energy Consumption Analysis of Highway Tunnel Lighting under Different Lamp Combination Modes
With the rapid development of highways,the number of tunnel lighting fixtures that ensure driver safety is increasing,and energy consumption is also increasing.It is urgent to find more energy-efficient lighting fixture combinations.This article reviews the current research status of tunnel lighting through Citespace,and compares and analyzes the daily electricity consumption of five lighting fixture combinations in a certain tunnel in Guangdong Province,based on the Guidelines for the Design of Highway Tunnel Lighting,while fully ensuring driving safety.Through comparative analysis of the calculation results,it is concluded that the combination of HPS+white light LED+HPS has the highest safety;the combination of golden LED+white LED+golden LED has the lowest energy consumption and higher safety;in the case of full line HPS,the energy consumption is the highest.