首页|分体式金属面板灯具控制装置放置对CDNE辐射骚扰测试的影响

分体式金属面板灯具控制装置放置对CDNE辐射骚扰测试的影响

扫码查看
通过验证分析发现分体式金属面板灯具在进行CDNE法辐射测试时,控制装置的放置位置对测试结果影响很大.企业实验室或第三方检测机构工程师在进行该类产品测试时,如果未考虑到该差异可能对测试结果产生影响,就会导致对产品造成误判的可能.本文通过实例来验证这一观点,并为广大检测人员在对这类产品进行CDNE法辐射检测时提供参考.
Effect of Different Placement Methods on CDNE Radiated Disturbance of Split Metal Panel Luminaire
According to the verification,the test results are quite different based on different setting position of controlgear when the Split metal panel light luminaire is applying the CDNE Radiated disturbance.If the engineers of enterprise laboratories or third-party testing institutions do not take into account the impact of such differences on the test results when testing such products,it will lead to the possibility of misjudgment of the products.The essay is to illustrate the perspective by actual examination and convey some references for those people who are getting involved in the testing of CDNE Radiated disturbance for these kind of products.

CDNEradiated disturbancesplit metal panelcontrolgearsetting position

胡江亮、蔡金标、刘琼、斯俊出、金梅玲

展开 >

横店集团得邦照明股份有限公司,浙江 东阳 322100

CDNE 辐射骚扰 分体式金属面板灯具 控制装置 放置位置

2024

中国照明电器
中国照明电器协会 国家轻工业照明电器信息中心 北京电光源研究所

中国照明电器

影响因子:0.271
ISSN:1002-6150
年,卷(期):2024.(12)