中国资源综合利用2024,Vol.42Issue(2) :10-16.DOI:10.3969/j.issn.1008-9500.2024.02.004

电感耦合等离子体原子发射光谱法测定尾气净化用金属载体催化剂中的铂、钯和铑含量

Determination of Platinum,Palladium,and Rhodium Content in Metal Carrier Catalysts for Exhaust Gas Purification by Inductively Coupled Plasma Atomic Emission Spectroscopy

王才平 陈能 郁丰善 黄庆 刘贵清 何治鸿 王翀 张保明 杨帆 张金良 刘成鹏
中国资源综合利用2024,Vol.42Issue(2) :10-16.DOI:10.3969/j.issn.1008-9500.2024.02.004

电感耦合等离子体原子发射光谱法测定尾气净化用金属载体催化剂中的铂、钯和铑含量

Determination of Platinum,Palladium,and Rhodium Content in Metal Carrier Catalysts for Exhaust Gas Purification by Inductively Coupled Plasma Atomic Emission Spectroscopy

王才平 1陈能 1郁丰善 2黄庆 1刘贵清 3何治鸿 1王翀 1张保明 3杨帆 2张金良 2刘成鹏1
扫码查看

作者信息

  • 1. 横峰县凯怡实业有限公司
  • 2. 江西省君鑫贵金属科技材料有限公司,江西 上饶 335500
  • 3. 江苏北矿金属循环利用科技有限公司,江苏 徐州 221121
  • 折叠

摘要

如何精准地测定汽车尾气催化剂的贵金属含量(铂、钯、铑),对于控制贵金属的成本、回收贵金属及控制催化剂的性能具有重要意义.试验采用电感耦合等离子体原子发射光谱法来测定尾气用净化金属载体催化剂中的铂(Pt)、钯(Pd)和铑(Rh)含量.具有而言,含有尾气净化用金属载体催化剂的试样采用盐酸进行预处理,然后加入聚环氧乙烷溶液降低胶粒对过滤的影响,过滤产物在马弗炉(300℃)内进行炭化处理,并加入 20 g Na2O2,经过沉淀凝聚实现富集分离.最后,采用电感耦合等离子体原子发射光谱仪对分离的铂、钯、铑的含量进行测定.在样品测定过程中,Pt、Pd和Rh的加标回收率分布范围表现良好,分别为 97.1%~109.0%、91.0%~101.8%和 93.2%~102.2%.该方法具有快速定量分析、检出限较低、精密度良好、动态范围宽的特点,为贵金属检测行业的标准制定奠定了数据理论支撑.

Abstract

How to accurately determine the precious metal content(platinum,palladium,rhodium)of automotive exhaust catalysts is of great significance for controlling the cost of precious metals,recovering precious metals,and controlling the performance of catalysts.The experiment uses inductively coupled plasma atomic emission spectroscopy to determine the content of platinum(Pt),palladium(Pd),and rhodium(Rh)in the purification metal carrier catalyst for exhaust gas.Specifically,the sample containing a metal carrier catalyst for tail gas purification is pretreated with hydrochloric acid,and then a solution of polyethylene oxide is added to reduce the influence of particles on filtration,and the filtered product is carbonized in a muffle furnace(300℃)and 20 g of Na2O2 is added for enrichment and separation through precipitation and coagulation.Finally,the content of separated platinum,palladium,and rhodium is determined by using an inductively coupled plasma atomic emission spectrometer.During the sample determination process,the spiked recoveries of Pt,Pd,and Rh show a good range distribution,ranging from 97.1%to 109.0%,91.0%to 101.8%,and 93.2%to 102.2%,respectively.This method has the characteristics of rapid quantitative analysis,low detection limit,good precision,and wide dynamic range,laying a theoretical foundation for the formulation of standards in the precious metal detection industry.

关键词

电感耦合等离子体原子发射光谱法/尾气净化用金属载体催化剂////测定

Key words

inductively coupled plasma atomic emission spectroscopy/metal carrier catalysts for exhaust gas purification/platinum/palladium/rhodium/determination

引用本文复制引用

基金项目

上饶市人才创新创业项目(2023年度)()

江西省双千计划首届培养类高端科技创新人才项目(jxsq2019201113)

上饶市"揭榜挂帅"项目(2022A005)

出版年

2024
中国资源综合利用
徐州北矿金属循环利用研究所 中国物资再生协会

中国资源综合利用

CHSSCD
影响因子:0.358
ISSN:1008-9500
参考文献量10
段落导航相关论文