中华创伤杂志(英文版)2021,Vol.24Issue(5) :301-305.

A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures

Ratish Kumar Mishra Bhagwati Prasad Sharma Amit Kumar Rohit Sherawat
中华创伤杂志(英文版)2021,Vol.24Issue(5) :301-305.

A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures

Ratish Kumar Mishra 1Bhagwati Prasad Sharma 2Amit Kumar 3Rohit Sherawat4
扫码查看

作者信息

  • 1. Orthopedic Department,Sir Gangaram Hospital,New Delhi 11006,India
  • 2. Central Institute of Orthopedics,Vardhman Mahavir Medical College and Safdarjung Hospital,New Delhi 110029,India
  • 3. Orthopedic Department,All India Institute of Medical Sciences,Rae Bareli 229405,India
  • 4. Central Institute of Orthopaedics,Vardhman Mahavir Medical College and Safdarjung Hospital,New Delhi 110029,India
  • 折叠

Abstract

Purpose:Comminuted intraarticular distal radial fractures are difficult to treat conservatively and require operative treatment.This study compared the functional outcomes between variable angle volar plating and external fixator with K-wire augmentation in open reduction and internal fixation.Methods:A total of 62 adult patients with comminuted intraarticular distal radius fracture were ran-domized into 2 groups:volar plate group and external fixator group.These patients aged between 18 and 60 years had unilateral fractures,and agreed to be included in the study.Patients with a history of fracture,bilateral fracture,associated other injuries,delayed injury for more than 2 weeks,open fracture,pre-existing arthrosis or disability,psychiatric illness and pathological fracture were excluded.Patients were followed up at 6 weeks,3 months,6 months and 1 year.The assessment of pain,functional activity,range of motion and grip strength was done at each stage of follow-up.The pain and functional activities were assessed by patient rated wrist evaluation (PRWE) score and disabilities of the arm,shoulder and hand (DASH) score.Results:Patients in volar plate group had superior PRWE score and DASH score at each stage of follow-up.At 1 year follow-up,the mean PRWE score were 7.48 for volar plate group and 7.35 for external fixator group;while the mean DASH score was 4.65 for volar plate group and 5.61 for external fixator group.They had better flexion and extension range of movement.They also had better pronation and supination range of motion at initial follow-up,however the difference get attenuated by 1 year.Volar plate group had significantly better grip strength than external fixator group.Complication rates were higher in external fixation group.Conclusion:Fixation with variable angle volar plate results in early wrist mobilization,better range of movement,less pain and disability and early return of function.

Key words

Comminuted/Distal radius fracture/Intraarticular/Volar plate/External fixator

引用本文复制引用

出版年

2021
中华创伤杂志(英文版)
中华医学会

中华创伤杂志(英文版)

CSTPCDCSCD
影响因子:0.608
ISSN:1008-1275
被引量1
参考文献量20
段落导航相关论文