首页|某超高层建筑空调冷凝水回收系统设计

某超高层建筑空调冷凝水回收系统设计

扫码查看
本文浅述空调冷凝水回收用于冷却水系统补水相关技术,并总结冷凝水开式回收和闭式回收的差异。介绍了空调冷凝水产水量、冷却塔补水量冷却塔补水水箱容量的计算方法,并以此为基础,结合广州某超高层建筑,对其空调冷凝水回收系统进行设计应用,为今后空调冷凝水回收系统设计提供参考。
Design of Condensate Water Recovery System for Air Conditioning in a Super High-rise Building
This article introduces the technologies related to the use of air conditioning condensate recovery for cooling water system replenishment,and summarizes the differences between open and closed condensate recovery.This article elaborates on the calculation method for the water volume of air conditioning condensate and the capacity of the cooling tower makeup water tank.Based on this,taking the air conditioning system of a super high-rise building in Guangzhou as an example,the design of the air conditioning condensate recovery system is carried out,providing reference for the future design of the air conditioning condensate recovery system.

Super High-rise BuildingAir conditioning CondensateRecycle

周庆申

展开 >

广东贝林建筑设计有限公司,广州,511400

超高层建筑 空调冷凝水 回收利用

2024

制冷
广东省制冷学会,福建省制冷学会,河南省制冷学会,云南省制冷学会,广西区制冷学会

制冷

影响因子:0.432
ISSN:1005-9180
年,卷(期):2024.43(2)