首页|帐篷类半室外场所空调系统应用效果分析

帐篷类半室外场所空调系统应用效果分析

扫码查看
本文主要研究在帐篷类半室外场所空调系统的应用效果。利用CFD模拟分析技术,以位于亚热带季风气候的深圳地区为场所所在地,以地面送风空调器为空调末端,以无风条件和季风条件两种情况为模拟环境,研究在此类场所有/无空调系统、空调末端送风口在室内侧/室外侧、送风角度与水平地面夹角为45°/80°时帐篷内的热环境,并进行对类似工程的实地考察测量,找出在此类场所应用空调系统的弊端,并提出有效的改善措施。
Analysis of the Application Effect of Tent-Type Semi-Outdoor Air Conditioning Systems
This paper primarily explores the application effect of air conditioning systems in tent-type semi-outdoor spaces.Utilizing Computational Fluid Dynamics(CFD)simulation analysis technology,the study focuses on a location in ShenZhen,which is situated in a subtropical monsoon climate.It considers ground-level air conditioners as the air conditioning end terminals,simulating two scenarios:no wind conditions and monsoon conditions.The research investigates the thermal environment inside the tent under various conditions,including the presence or absence of air conditioning systems,the positioning of air conditioning end terminals on the indoor or outdoor side,and the angle of airflow delivery relative to the horizontal ground(45°/80°).Field inspections and measurements similar to such engineering projects are conducted to identify drawbacks in the application of air conditioning systems in such spaces and propose effective improvement measures.

TentAir Conditioning SystemCFD SimulationThermal EnvironmentSemi-Outdoor Air Conditioning Space

廖捷、廖勇坤

展开 >

广东省建筑设计研究院有限公司,广州,510010

帐篷 空调系统 CFD模拟 热环境 半室外空调场所

2024

制冷
广东省制冷学会,福建省制冷学会,河南省制冷学会,云南省制冷学会,广西区制冷学会

制冷

影响因子:0.432
ISSN:1005-9180
年,卷(期):2024.43(5)