首页|直接胆红素对全自动生化分析仪黄疸指数测量的影响

直接胆红素对全自动生化分析仪黄疸指数测量的影响

扫码查看
目的 研究在全自动生化分析仪黄疸指数测量中直接胆红素的影响。方法 选择2021年7月—2023年7月需要在本院测量黄疸指数的患者40例作为数据研究对象,对其均进行黄疸指数、总胆红素、直接胆红素检测。依据直接胆红素占总胆红素比例,将其分成两组,对照组为占比<50%,观察组为占比≥50%。对比两组总胆红素、直接胆红素、黄疸指数;对比直接胆红素与黄疸指数的相关性。结果 观察组总胆红素水平与对照组无明显差异(P>0。05);观察组直接胆红素水平显著高于对照组,黄疸指数显著低于对照组(P<0。05);Spearman相关性分析显示,对照组与观察组相关系数分别为0。912,0。937(P<0。001),整体呈线性关系,高度相关。结论 在全自动生化分析仪黄疸指数测量中,直接胆红素会对其产生一定影响,在测量黄疸指数时,可以结合其他指标,确保结果准确性。
Effect of Direct Bilirubin on Measurement of Jaundice Index with Fully Automated Biochemical Analyzer
Objective To study effect of direct bilirubin in measurement of jaundice index with fully automated biochemical analyzer.Methods The paper chose 40 patients with measurement of jaundice index in our hospital from July 2021 to July 2023 as study subjects,tested jaundice index,total bilirubin and direct bilirubin,and divided them into two groups according to proportion of direct bilirubin to total bilirubin:control group had proportion of<50%,and observation group had proportion of≥50%.Total bilirubin,direct bilirubin and jaundice index,correlation between direct bilirubin and jaundice index was compared between two groups.Results There was no significant difference in total bilirubin levels between observation group and control group(P>0.05).The direct bilirubin level in observation group was(19.20±2.25)µ mmol/L,significantly higher than control group,while jaundice index was(28.28±3.45)µ mmol/L in observation group,significantly lower than control group(P<0.05).Spearman correlation analysis showed,correlation coefficients between control group and observation group were 0.912 and 0.937 respectively(P<0.001),showing overall linear relationship and high correlation.Conclusion Direct bilirubin can have some certain effect during measurement of jaundice index with fully automated biochemical analyzer.When measuring jaundice index,other indicators can be combined to ensure accuracy of the results.

Direct bilirubinFully automatic biochemical analyzerJaundice index measurement

张丽芹

展开 >

射阳县海通镇卫生院 检验科,江苏 盐城 224343

直接胆红素 全自动生化分析仪 黄疸指数测量

2024

智慧健康

智慧健康

ISSN:
年,卷(期):2024.10(8)
  • 10