摘要
文章通过对某热电公司350MW超临界锅炉燃用混煤导致结焦的原因进行分析,找出问题所在,采取一系列针对性强的措施,适当进行设备改造,有效缓解了结焦现象,提高了锅炉对混煤的适应性,实现了机组可长周期高负荷安全运行的目标。
Abstract
The coke forming mechanism that combust mixed coalin 350MW supercritical pressure boiler was analyzed, and a series of pertinence countermeasures was proposed which effectively alleviate coking boiler, and improve the boiler practicability with combustion mixed coal. The destination make that the unit works in long period and high load come true.
关键词
锅炉/结焦/控制Key words
boiler/coking/control引用本文复制引用