浙江化工2024,Vol.55Issue(7) :50-54.DOI:10.3969/j.issn.1006-4184.2024.07.008

微波与电热板消解-ICP-OES法测定汽车涂料中的总铅含量

Determination of Total Lead Content in Automotive Coatings by Microwave and Electrothermal Plate Digestion-ICP-OES

万日坚 卢家俊 李晓增 叶元坚 钟俊芳
浙江化工2024,Vol.55Issue(7) :50-54.DOI:10.3969/j.issn.1006-4184.2024.07.008

微波与电热板消解-ICP-OES法测定汽车涂料中的总铅含量

Determination of Total Lead Content in Automotive Coatings by Microwave and Electrothermal Plate Digestion-ICP-OES

万日坚 1卢家俊 1李晓增 1叶元坚 1钟俊芳1
扫码查看

作者信息

  • 1. 广州质量监督检测研究院,广东 广州 511447;广州市NQI-质量安全科技协同创新中心,广东 广州 511447
  • 折叠

摘要

分别采用微波高压密闭消解法和电热板消解法将汽车涂料中的铅消解完全,制成样品溶液后,用电感耦合等离子体发射光谱法(ICP-OES)测定样品溶液中的总铅含量.对两种消解方法的样品测定结果进行比较,微波消解法总铅含量的加标回收率为 95.6%~98.1%,电热板消解法总铅含量的加标回收率为 97.4%~101.2%.经验证,微波消解法具有耗时短、试剂用量少以及安全性、精确度和准确度较高等优点.

Abstract

The lead in automotive coatings was completely digested using microwave high-pressure sealed digestion method and electrothermal plate digestion method,respectively,and then prepared into a sample solution.The total lead content in the sample solution was determined using inductively coupled plasma optical emission spectroscopy(ICP-OES).Comparing the sample determination results of two digestion methods,the spiked recovery rate of total lead content by microwave digestion method is 95.6%~98.1%,and the spiked recovery rate of total lead content by electrothermal plate digestion method is 97.4%~101.2%.After verification,microwave digestion method has the advantages of shorter time consumption,less reagent dosage,and higher safety,accuracy and precision.

关键词

微波消解/电热板消解/汽车涂料/总铅含量

Key words

microwave digestion/electrothermal plate digestion/automotive coatings/total lead content