首页|采用真空绝热板的冷热双效保温箱设计

采用真空绝热板的冷热双效保温箱设计

扫码查看
设计一种真空绝热板(VIPs)与半导体制冷技术相结合的保温箱,为了对比内保温(半导体制冷装置-导温板-VIPs)和外保温(VIPs-半导体制冷装置-导温板)2种设计方案的保温箱内部温度分布均匀性,建立三维模型进行模拟,在同样的条件下进行试验,并测试2~8 ℃的保温时长.结果表明:内保温设计方案保温箱内部温度分布均匀;当半导体制冷装置未启动时,外保温设计方案保温箱内壁面温度差异较大;内保温设计方案优于外保温设计方案,采用内保温设计方案的保温箱内2~8 ℃的最长保温时间为35 h.
Design of insulated container with refrigeration and heating function using vacuum insulation panels
An insulated container combining vacuum insulation panels(VIPs)and sem-iconductor refrigeration technology is designed.In order to compare the uniformity of in-sulated container internal temperature distribution of two design schemes,internal insula-tion(semiconductor-temperature conducting plate-VIPs)and external insulation(VIPs-semiconductor-temperature conducting plate),a three-dimensional model is established for simulation,and then experiments are carried out under the same condition to test the insultation duration in the range of 2-8 ℃.The results show that:the internal tempera-ture distribution of the insulated container with internal insulation design scheme is uni-form;when the semiconductor refrigeration is not started,the temperature difference of the inner wall of the insulated container under the external insulation design scheme is large;the internal insulation design scheme is better than the external insulation design scheme,and the longest insulation time of the insulated container with the internal insula-tion design scheme is 35 h in the range of 2-8 ℃.

cold chain transportinsulated containervacuum insulation panelssemi-conductor refrigeration

于凌爽、张婷婷、阚安康、陈照峰、张亮亮

展开 >

上海海事大学商船学院

上海市制冷学会

南京航空航天大学材料科学与技术学院

江苏山由帝奥节能新材股份有限公司

展开 >

冷链运输 保温箱 真空绝热板 半导体制冷

国家自然科学基金联合基金(核技术)重点支持项目

U2167214

2024

制冷与空调
中国制冷空调工业协会 中国科学技术交流中心

制冷与空调

影响因子:0.331
ISSN:1009-8402
年,卷(期):2024.24(2)
  • 13