制冷与空调2024,Vol.24Issue(4) :46-51.DOI:10.3969/j.issn.1009-8402.2024.04.008

基于双机头串联逆流的大温差水蓄冷空调系统的应用

Large temperature difference water storage air conditioning system based on double head series counterflow

张浩 李奇 曹长鸣
制冷与空调2024,Vol.24Issue(4) :46-51.DOI:10.3969/j.issn.1009-8402.2024.04.008

基于双机头串联逆流的大温差水蓄冷空调系统的应用

Large temperature difference water storage air conditioning system based on double head series counterflow

张浩 1李奇 1曹长鸣1
扫码查看

作者信息

  • 1. 珠海格力电器股份有限公司
  • 折叠

摘要

介绍了基于双机头串联逆流的大温差水蓄冷空调系统的工作原理,除湿方式及系统特点.主机部分采用双机头串联逆流,末端部分为组空机组,采用两级表冷,热湿联合处理的形式,同时采用了大温差蓄能,解决了水蓄冷系统蓄冷容积过大的问题.最后将该系统运用于某展厅,此系统较常规系统减小设备容量、蓄冷密度大、大幅度减小蓄冷槽体积,利用夜间低价电力蓄冷,大幅减少了运行费用.

Abstract

The working principle,dehumidification mode and system characteristics of large temperature difference water storage air conditioning system based on double head series reverse current are introduced.The main engine part adopts double head series counterflow,the end part is a group of empty units,using the form of two-stage surface cooling,heat and humidity combined treatment,and at the same time adopts large tem-perature difference energy storage,which solves the problem of excessive cold storage vol-ume of water storage and cooling system.Finally,the system is applied to a certain exhi-bition hall,which reduces the equipment capacity,the cold storage density is large,the volume of the cold storage tank is greatly reduced,and the low-cost electricity storage at night is used to greatly reduce the operating costs.

关键词

双冷源/两级表冷/大温差/串联逆流

Key words

double cold source/two-stage table cooling/large temperature difference/series countercurrent

引用本文复制引用

出版年

2024
制冷与空调
中国制冷空调工业协会 中国科学技术交流中心

制冷与空调

影响因子:0.331
ISSN:1009-8402
段落导航相关论文