首页|中深层地埋管地源热泵系统优化配置研究

中深层地埋管地源热泵系统优化配置研究

扫码查看
中深层地埋管地源热泵系统作为建筑热源,具有能效高、污染小等特点.本文针对中深层地埋管地源热泵系统的优化配置进行研究,基于建筑实际用能需求,利用中深层地埋管换热模型仿真结果,与实测数据进行"反算"拟合,得到地下岩土体综合热物性参数.进一步采用理论计算、动态仿真手段,进行不同运行策略下的中深层地埋管换热动态仿真计算,开展中深层地埋管地下岩土体温度变化、地埋管进口和出口温度数据分析,实现中深层地埋管地源热泵系统配置方案优化.在本文计算条件下,当中深层地埋管地源热泵系统承担项目设计热负荷时,需要配置65个2 500 m深的地埋管换热器;当充分发挥中深层地埋管地源热泵系统供热能力,承担最大恒定热负荷时,24个地埋管换热器即可满足建筑累计热负荷需求.因此,为兼顾系统初投资及运行性能,本文建议热源采用中深层地埋管地源热泵+辅助热源的复合式系统形式,由中深层地埋管地源热泵系统承担基础负荷,充分发挥系统供热能力,提高系统经济性.
Optimizing configuration of middle-deep buried pipe ground source heat pump systems
As a building heat source,middle-deep buried pipe ground source heat pump systems have the characteristics of high energy efficiency and low pollution.Aiming at the research on the optimizing configuration of middle-deep buried pipe ground source heat pump systems,based on the actual energy demand of buildings,the simulation results of the heat transfer model of middle-deep buried pipes are fit by the measured data through reverse calculation,so as to obtain the comprehensive thermal properties of underground rock and soil.Furthermore,the theoretical calculations and dynamic simulation methods are used to conduct dynamic simulation calculations of heat transfer in middle-deep buried pipes under different operating strategies.By analyzing the temperature changes of under-ground rock and soil,inlet and outlet temperature data of buried pipes,the optimizing configuration scheme of middle-deep buried pipe ground source heat pump systems is a-chieved.Under the calculation conditions in this article,when the middle-deep buried pipe ground source heat pump system bears the design heating load of the project,sixty-five buried pipe heat exchangers with 2 500 m depth need to be configured.To fully utilize the heating capacity of the middle-deep buried pipe ground source heat pump systems under the maximum constant heating load,only twenty-four buried pipe heat exchangers are needed to meet the cumulative heat load demand of the building.Therefore,to balance the initial investment and operational performance of the system,the heat source should adopt a composite system form of middle-deep buried pipe ground source heat pump and auxiliary heat source,with the middle-deep buried pipe ground source heat pump system bearing the basic load,to fully utilize the heating capacity of the system and improve sys-tem economy.

middle-deep geothermal energyground source heat pumpoptimizing con-figurationthermal response of rock and soildynamic simulationoperational strategy

孙志云、陈贺伟、韦启珍、李俊宇、卢小龙、唐远程、崔志恒

展开 >

中国能源建设集团湖南省电力设计院有限公司

中深层地热能 地源热泵 优化配置 岩土热响应 动态模拟 运行策略

2024

制冷与空调
中国制冷空调工业协会 中国科学技术交流中心

制冷与空调

影响因子:0.331
ISSN:1009-8402
年,卷(期):2024.24(8)