首页|办公与商业建筑消防配电设计优化探讨

办公与商业建筑消防配电设计优化探讨

扫码查看
文章分析了办公与商业建筑消防配电设计的特点和要求,对比了早期消防配电方案与《民用建筑电气设计标准(GB 51348-2019)》施行后的新方案。通过对现行方案的分析,指出存在的问题,并提出优化方案,包括合理设置双电源切换箱、优化线路和控制箱配置、灵活选择末端切换箱安装位置等措施。同时,文章还讨论了消防配电线路的线缆选择和敷设要求。优化后的设计方案能够在保障消防安全的前提下,有效简化系统,降低成本,提高效率。
Discussion on Optimization of Fire Protection Power Distribution Design for Office and Commercial Buildings
This paper analyzes the characteristics and requirements of fire protection power distribution design in office and commercial buildings,and compares the early fire protection power distribution scheme with the new scheme after the implementation of the "Standard for electrical design of civil buildings (GB 51348-2019)". Through the analysis of the current scheme,the existing problems are pointed out,and optimization schemes are proposed,including reasonable settings of dual power switch boxes,optimization of wiring and control box configurations,and flexible selection of the installation positions of terminal switch boxes. Meanwhile,the paper also discusses the cable selection and laying requirements for fire protection power distribution lines. The optimized design scheme can effectively simplify the system,reduce costs,and improve efficiency under the premise of ensuring fire safety.

fire protection power distribution designoffice and commercial Buildingsdual power switch boxoptimization schemewiring system

李忠良

展开 >

深圳市荣超房地产开发有限公司

消防配电设计 办公与商业建筑 双电源切换箱 优化方案 布线系统

2024

智能建筑与智慧城市
中国勘察设计协会

智能建筑与智慧城市

影响因子:0.317
ISSN:2096-1405
年,卷(期):2024.(z1)