文章通过一个实际的工程项目,浅谈人防设计中人防负荷等级、人防柴油电站设置原则、机组容量及台数选择、人防发电机机房配合要点,为设计人员提供一些参考.

Abstract

This paper discusses the load grade of civil air defense,the setting principles of civil air defense diesel power stations,the selection of unit capacity and quantity,and the key points for coordinating civil air defense generator rooms in civil air defense design through a practical engineering project,providing some references for designers.

关键词

人防电站/负荷分级/战时电源/人防柴油机容量

Key words

civil air defense power station/load classification/wartime power supply/civil air defense diesel engine capacity