低剂量MSCT在PPD阳性人群肺结核筛查的可行性研究

扫码查看
目的:本研究的目的是探讨首次接受低剂量MSCT筛查PPD阳性人群肺结核的应用价值。方法选择156例PPD阳性肺结核病人随机分成50mA、30m A、20m A三组行16排螺旋C T低剂量胸部扫描,扫描范围从肺尖至双肋膈角。然后对进行比较的病例使用设备默认条件进行常规扫描:扫描电压均为120K V、电流250m A、层厚7.5m m、螺距1.375:1、速度(m m/r o t)27.50。在工作站上对各组低剂量扫描和常规扫描肺内结核病灶的C T值标准偏差、噪声值以及表面入射剂量采用配对t检验法进行统计学比较分析。结果在肺结核病灶的CT影像学显示方面,低剂量组中50mA、30mA图像和常规剂量扫描图像相比无统计学差异(P>0.05),但20mA组少数体重较大病人影像噪声明显增加,影响了肺结核病灶的显示,与50mA、30mA低剂量组及常规剂量组相比有统计学差异(P<0.05)。常规剂量组及50mA、30mA、20mA低剂量组表面入射剂量分别为13.4mGy、2.72 mGy、1.63 mGy、1.09 mGy,低剂量组较常规剂量组分别降低了79.7%、87.9%、和91.8%。结论30mA胸部低剂量CT扫描完全可以取代常规剂量CT进行PPD阳性人群肺结核的筛查。
Low dose MSCT in PPD positive population screening for pulmonary tuberculosis feasibility study
Objective To investigate the low dose MSCT in PPD positive people, the value of screening for pulmonary tuberculosis. Methods 156 cases of PPD positive patients with pulmonary tuberculosis were 16 row spiral CT chest scans, first use the device default conditions were routine scan : a scanning voltage is 120KV, current 250mA, thickness of 7.5mm, pitch 1.375 : 1, speed ( mm / rot ) 27.50, the scanning range from the apex to the double rib diaphragm angle. Were randomly divided into three groups in the region of the lesion were treated with conventional dose, 50mA, 30mA, 20mA scanning, the scanning conditions and conventional scanning completely consistent, on a workstation for conventional scanning and a variety of low dose scanning pulmonary tuberculosis CT value standard deviation, the value of the noise and the entrance surface dose using the paired t test method were statistical y compared analysis. Results In pulmonary tuberculosis CT imaging display, conventional dose scanning and low dose group in 50mA, 30mA showed no statistical difference ( P > 0.05 ), but 20mA group a weight larger patient image noise significantly increased, affecting the pulmonary tuberculosis showed, compared with conventional dose and low dose group compared to 50mA, 30mA there was statistical y significant difference ( P < 0.05 ). Conventional dose group and 50mA, 30mA, 20mA and low dose group of entrance surface dose were 13.4mGy, 2.72 mGy, 1.63 mGy, 1.09 mGy, low dose group than in conventional dose group were decreased by 79.7%, 87.9%, and 91.8%. Conclusions 30mA of thorax low dose CT scan can completely replace conventional doses of CT were PPD positive population tuberculosis screening.

lungpulmonary tuberculosistomographyX-ray computedradiation dose

梁昌胜、孙民峰、王新华、吴瑜、刘俊忠、孙玉霞、李小山

展开 >

山东省潍坊市第二人民医院放射科 261041

肺结核 体层摄影术 X线计算机 放射剂量

2014

中外健康文摘
中国中医药报社

中外健康文摘

影响因子:0.016
ISSN:1672-5085
年,卷(期):2014.(3)
  • 2
  • 2