首页|(105892)Failure analysis of ESD damage on interconnects in LCD GOA

(105892)Failure analysis of ESD damage on interconnects in LCD GOA

扫码查看
Liquid crystal display (LCD) is likely to accumulate charge and incur ESD events due to the insulating glass plate. In our study, an ESD induced failure of interconnects in LCD gate driver on array (GOA) was analyzed. The monochrome pattern test was conducted to locate the failure site. The morphology of the failure site was characterized by SEM, EDS and FIB. Charge accumulation on long interconnects in the VUV-cleaning process, and subsequent discharging damage at narrow interconnect gaps were analyzed to be the root cause of failure. Furthermore, some specimens were designed to validate the analysis, design of experiments was performed to study the effects of the gap space and the interconnect length on the failure severity. Based on the experimental data, a logistic model was developed to model the failure severity, which can help to provide suggestions for designs to reduce the incidence of failures.

Liquid Crystal Display (LCD)Electrostatic Discharge (ESD)Gate driver on array (GOA)VUV cleaningInterconnects failure

Ye Wang、Guicui Fu、Pengcheng Tian

展开 >

School of Reliability andSystems Engineering, Beihang University, Beijing 100191, China

BOE Optoelectronics Technology CO., LTD., Beijing 100176, China

2022

Engineering failure analysis

Engineering failure analysis

EISCI
ISSN:1350-6307
年,卷(期):2022.131
  • 19