首页|(105885)Failure analysis of areal gas distribution skirt plate
(105885)Failure analysis of areal gas distribution skirt plate
扫码查看
点击上方二维码区域,可以放大扫码查看
原文链接
NSTL
Elsevier
A detailed failure analysis was carried out on a skirt plate used in the reduction shaft of Corex plant at Areal Gas Distribution that failed after seven years of service. The analysis involved composition, hardness, mechanical properties, impact toughness, microstructure and phase analysis in the failed plate, and after solution annealing the plate for different lengths of time. It was found that the plate completely embrittled due to formation of massive Cr_(23)C_6 type carbides and σ-phase (FeCr) for prolonged service at high temperature (- 850 C), observed through microstructure and EDS analysis).The elongation of the steel was reduced to 1-4% and impact energy dropped to 5 Joule due to the embrittlement. The fracture surface showed intergranular brittle failure. After solution annealing treatment, the massive carbides and phases were mostly dissolved resulting in the restoration of the property. Hence it is suggested for solution annealing treatment in the in-service plates to improve their life. In addition, periodic monitoring of the plates through replica test and NDT could help in assessment of health of the plates for preventive measure.
AISI310S steelSigma phase embrittlementFailureMicrostructure and Mechanical properties
J.N. Mohapatra、Ravindra Kulkarni、D. Satish Kumar
展开 >
R&Dand SS, JSW Steel Limited, Toranagallu, Bellary 583275, India
Corex Plant, JSW Steel Limited, Toranagallu, BeUary 583275, India