首页|Comment on the paper "A scientific report of non-singular techniques on microring resonators: An application to optical technology, Kashif Ali Abro, Bhagwan Das, Optik 224 (2020) 165696 "

Comment on the paper "A scientific report of non-singular techniques on microring resonators: An application to optical technology, Kashif Ali Abro, Bhagwan Das, Optik 224 (2020) 165696 "

扫码查看
A serious error exists in the above paper. The equation (7) in [1] is as follows d2y(t) dt2 + ?? dy(t) dt + ??y(t) = x(t) (1) where the functions x(t) and y(t) are the input and output signals. From figure 2 in [1] it is seen that the units of parameter ?? are meters(length). From figure 3 in [1] it is seen that the units of parameter ?? are also meters(length). From figure 4 in [1] it is seen that the units of parameter t are second(time). Thus the units of the terms in Eq. (1) are as follows d2y(t) dt2 : y(t)sec???2 ?? dy(t) dt : y(t)msec??? 1 ??y(t) : y(t)m In a Physics equation all terms must have the same units. For that reason the Eq. (1) is wrong. The entire work in [1] is based on Eq. (1). Taking into account that Eq. (1) is the basic equation in [1] it is obvious that all subsequent results are wrong. Superscript/Subscript Available</comment

Pantokratoras, Asterios

展开 >

Democritus Univ Thrace

2022

Optik

Optik

EISCI
ISSN:0030-4026
年,卷(期):2022.261
  • 1