Applied thermal engineering2022,Vol.20021.DOI:10.1016/j.applthermaleng.2021.117710

Temperature control of vibrating heat-generating hardware using spray evaporative cooling in the nucleate boiling region

Sarmadian, A. Dunne, J. F. Jose, J. Thalackottore Pirault, J-P Long, C. A.
Applied thermal engineering2022,Vol.20021.DOI:10.1016/j.applthermaleng.2021.117710

Temperature control of vibrating heat-generating hardware using spray evaporative cooling in the nucleate boiling region

Sarmadian, A. 1Dunne, J. F. 1Jose, J. Thalackottore 1Pirault, J-P 1Long, C. A.1
扫码查看

作者信息

  • 1. Univ Sussex, Sch Engn & Informat, Dept Engn & Design, Brighton BN1 9QT, E Sussex, England
  • 折叠

Abstract

A temperature control approach using evaporative spray cooling of vibrating surfaces in the nucleate boiling region is proposed and verified experimentally. This is relevant to temperature control of heat-generating automotive vehicle components. By exploiting an experimentally calibrated dynamic correlation model to represent evaporative spray cooling of a flat test-piece, a PID controller has been adopted with emphasis focused on the choice of gain parameters to ensure both stability of temperature control, and favourable responses in terms of relevant performance measures. Optimum linearisation of the correlation model has been achieved by solving an appropriate Wiener-Hopf equation, mainly to undertake a practical stability assessment of the closedloop temperature control system. To verify the predicted control system performance, experimental measurements have been obtained from an instrumented, and spray-evaporatively-cooled, flat test-piece exposed to displacement vibration from a shaker. Experimental testing, appropriate to automotive vehicle component applications, includes large-amplitude, low frequency vibration at 12 mm and 1.9 Hz, and low amplitude, highfrequency vibration at 0.02 mm and 400 Hz. To assess the effects of different PID controller gains on the thermal performance of the thermal management system, a coefficient of performance (COP) is used, defined as the ratio of heat power removal to the required pumping power. To achieve a reduction in the settling time, and an increase in the rise time of stable control, a PID controller with a negative proportional gain showed most promising results. A 10.5% increase in COP was achieved in comparison to a PID controller with positive gains. This information is useful for the design and optimization of thermal management systems using evaporative spray cooling.

Key words

Thermal management/Spray evaporative cooling/Vibrating surfaces/PID Control/Hardware-based experimental verification/Automotive and aerospace applications

引用本文复制引用

出版年

2022
Applied thermal engineering

Applied thermal engineering

EISCI
ISSN:1359-4311
被引量7
参考文献量69
段落导航相关论文